A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Method Transfer Evaluation for Digital Derivative Spectrophotometry Through its Resolution Parameter Comparison of Different Computer Programs. | LitMetric

The application assessment of different programs was performed with equivalence tests for method transfer pro second-order derivative spectrophotometry. The digital second-order derivative spectra were calculated on different instruments; GBC Scientific Equipment Cintra 20 (Cintral v.2.6 and Spectral v.1.70 software programs) and Thermo Scientific Evolution 300 (VISIONPro software) were analyzed using the amplitude A/B ratio (A = D; B = D). Amplitude A/B ratio is the resolution parameter for derivative spectrophotometry prescribed in European Pharmacopoeia. The obtained values for A/B ratio were either very similar or significantly different among programs: 0.669 (Cintral v.2.6), 0.549 (Spectral v.1.70), 0.556 (medium indirect VISIONPro), 0.557 (one-step Savitzky-Golay 7 VISIONPro), 0.689 (two-step Savitzky-Golay 7 VISIONPro). Method transfer was possible between Spectral v.1.70 and VISIONPro (medium indirect and one-step Savitzky-Golay 7), but the values obtained in Cintral v.2.6 were not comparable to the other programs. The absorbance data exported from both instruments were additionally calculated in OriginPro8 which provided almost the same mean A/B values (0.627 Cintral v.2.6; 0.624 VISIONPro), confirming that the two instruments recorded the same zero-order spectra. The calculation of resolution parameter could be used for verification of program comparison, which would enable transfer between sender and receiver laboratory. The accordance between program algorithms was confirmed when acceptable differences for values of resolution parameter (A/B ratios) were achieved.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0003702819889374DOI Listing

Publication Analysis

Top Keywords

resolution parameter
16
cintral v26
16
method transfer
12
derivative spectrophotometry
12
spectral v170
12
a/b ratio
12
second-order derivative
8
amplitude a/b
8
medium indirect
8
one-step savitzky-golay
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!