The effect of simulated circumferential soft exoskeleton compression at the knee on discomfort and pain.

Ergonomics

School of Design, Health Research Institute and Confirm Smart Manufacturing Centre, University of Limerick, Limerick, Ireland.

Published: May 2020

There is a lack of data and guidance on soft exoskeleton pressure contact with the body. The purpose of this research was to study the relationship between circumferential loading at the knee and discomfort/pain, to inform the design of soft exoskeletons/exosuits. The development of discomfort and pain was studied during standing and walking with circumferential compression using a pneumatic cuff. Our results show higher tolerance for intermittent than continuous compression during standing. Discomfort was triggered at pressures ranging from 13.7 kPa (continuous compression) to 30.4 kPa (intermittent compression), and pain at 52.9 kPa (continuous compression) to 60.6 kPa (intermittent compression). During walking, cyclic compression caused an increase in discomfort with time. Higher cuff inflation pressures caused an earlier onset and higher end intensities of discomfort than lower pressures. Cyclic cuff inflation of 10 kPa and 20 kPa was reasonably well tolerated. Soft exoskeleton compression of the knee was simulated during static and dynamic compression cycles. The results can be used to understand how users tolerate pressure at the knee, and also to understand the levels at which discomfort and pain are experienced. BMI: body mass index; DDT: discomfort detection threshold; EndVAS: end of experiment rating on visual analog discomfort scale; PDT: pain detection threshold; SD: standard deviation; SE: standard error; TSP: temporal summation of pain; VAS: visual analogue scale.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00140139.2020.1743373DOI Listing

Publication Analysis

Top Keywords

soft exoskeleton
12
discomfort pain
12
continuous compression
12
compression
10
exoskeleton compression
8
compression knee
8
discomfort
8
intermittent compression
8
cuff inflation
8
detection threshold
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!