Fruit flies, Drosophila melanogaster, are active over a range of light intensities in the wild, but lab-reared flies are often tested only in bright light. Similarly, scarce feeding during larval stages-common in nature-generates smaller adults, and a wide range of eye sizes not found in well-fed lab colonies. Both dimmer light and smaller eyes limit light capture and have undetermined effects on visual behaviors such as flight. In this study, we used moving sinusoidal gratings to test spatial acuity, temporal acuity, and contrast threshold of female flies of varying eye sizes at different light intensities. We also investigated vision in the smaller and often neglected male fruit flies. As light intensity drops from 50.1 lx to 0.3 lx, flies have a reduced spatial acuity (females: from 0.1 to 0.06 cycles per degree, CPD, males: 0.1 to 0.04 CPD) and temporal acuity (females: from 50 Hz to 10 Hz, males: 25 Hz to 10 Hz), and an increased contrast detection threshold (females: from 10% to 29%, males: 19% to 48%). We find no major sex-specific differences after accounting for eye size. Visual abilities in both small (eye area of 0.1-0.17 mm) and large flies (0.17-0.23 mm) suffer at 0.3 lx compared to 50.1 lx, but small flies suffer more (spatial acuity: 0.03 vs 0.06 CPD, contrast threshold: 76% vs 57%, temporal acuity: 5 Hz vs 10 Hz). Our results suggest visual abilities of small flies suffer more than large flies at low light levels, possibly leading to size- and light intensity-dependent effects on foraging, navigation, and flight.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.visres.2020.02.007DOI Listing

Publication Analysis

Top Keywords

visual abilities
12
spatial acuity
12
temporal acuity
12
light
9
flies
9
drosophila melanogaster
8
fruit flies
8
light intensities
8
eye sizes
8
contrast threshold
8

Similar Publications

Neuroimaging research has increasingly used decoding techniques, in which multivariate statistical methods identify patterns in neural data that allow the classification of experimental conditions or participant groups. Typically, the features used for decoding are spatial in nature, including voxel patterns and electrode locations. However, the strength of many neurophysiological recording techniques such as electroencephalography or magnetoencephalography is in their rich temporal, rather than spatial, content.

View Article and Find Full Text PDF

Thanks to the plummeting costs of continuously evolving omics analytical platforms, research centers collect multiomics data more routinely. They are, however, confronted with the lack of a versatile software solution to harmoniously analyze single-omics and interpret multiomics data. We have developed iSODA, a web-based application for the analysis of single- and multiomics data.

View Article and Find Full Text PDF

Pericardial effusion refers to the accumulation of fluid within the pericardial sac, the double-layered membrane surrounding the heart. It can be caused by various medical conditions and may lead to serious complications if not diagnosed and managed promptly. Point-of-care ultrasound (POCUS) has emerged as a valuable tool in the clinical evaluation of pericardial effusions, offering real-time visualization and aiding in the assessment of its size, characteristics, and potential hemodynamic impact.

View Article and Find Full Text PDF

Optic nerve disorders significantly contribute to visual impairment with irreversible visual deficits. Current treatments have limited efficacy in resolving chronic visual deficits, necessitating novel therapeutic strategies. Neurorehabilitation techniques, including repetitive transorbital alternating current stimulation (rtACS), have emerged as promising approaches to restore lost visual function through the ability to modulate brain activity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!