Thoracic fluid content: a novel parameter for predicting failed weaning from mechanical ventilation.

J Intensive Care

Department of Anesthesia and Critical Care Medicine, Faculty of Medicine, Cairo University, 01 Elsarayah Street, Elmanyal, Cairo, 11559 Egypt.

Published: March 2020

Background: Weaning of patients from the mechanical ventilation remains one of the critical decisions in intensive care unit. This study aimed to evaluate the accuracy of thoracic fluid content (TFC) as a predictor of weaning outcome.

Methods: An observational cohort study included 64 critically ill surgical patients who were eligible for extubation. Before initiating the spontaneous breathing trial, the TFC was measured using the electrical cardiometry technology. Patients were followed up after extubation and divided into successful weaning group and failed weaning group. Both groups were compared according to respiratory and cardiovascular parameters. Receiver operating characteristic (ROC) curves were constructed to evaluate the ability of TFC to predict weaning outcome.

Results: The number of successfully weaned patients was 41/64 (64%). Twenty (31%) patients had impaired cardiac contractility, and of them, 13/20 (64%) patients were successfully extubated. Both groups, successful weaning group and failed weaning group, were comparable in most of baseline characteristics; however, the TFC was significantly higher in the failed weaning group compared to the successful weaning group. The area under the ROC curves (AUCs) showed moderate predictive ability for the TFC in predicting weaning failure (AUC [95% confidence interval] 0.69 [0.57-0.8], cutoff value > 50 kΩ), while the predictive ability of TFC was excellent in the subgroup of patients with ejection fraction < 40% (AUC [95% confidence interval 0.93 [0.72-1], cutoff value > 50 kΩ).

Conclusions: Thoracic fluid content showed moderate ability for predicting weaning outcome in surgical critically ill patients. However, in the subgroup of patients with ejection fraction less than 40%, TFC above 50 kΩ has an excellent ability to predict weaning failure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7059362PMC
http://dx.doi.org/10.1186/s40560-020-00439-2DOI Listing

Publication Analysis

Top Keywords

weaning group
24
failed weaning
16
weaning
13
thoracic fluid
12
fluid content
12
successful weaning
12
ability tfc
12
patients
9
mechanical ventilation
8
critically ill
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!