A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Control of wildfire-sourced PM2.5 in an office setting using a commercially available portable air cleaner. | LitMetric

Control of wildfire-sourced PM2.5 in an office setting using a commercially available portable air cleaner.

J Occup Environ Hyg

College of Letters, Sciences, and Professional Studies, Department of Biological Sciences, Montana Technological University, Butte, Montana.

Published: April 2020

A steady increase in wildfire event severity and season length has led to greater potential for exposure to fine particulate matter associated with wildfire smoke. Research has found fine particulate matter to be correlated with a myriad of health ailments and thus effective strategies for controlling exposures are needed. In this study, a correction factor associated with wildfire-sourced fine particulate matter was established for a TSI SidePak AM520 by conducting sampling with a co-located MetOne BAM 1020. Portable air cleaner efficacy was assessed by simultaneously measuring PM mass concentrations in two identical offices with the inclusion of a portable air cleaner in one. The relationship between indoor and outdoor PM mass concentrations was assessed by comparing concentrations recorded in an office to those recorded at the nearest National Ambient Air Quality Standards monitoring station. Results revealed that a portable air cleaner reduced indoor fine particulate matter within an office by 73% and 92% during working and non-working hours, respectively, and that a strong significant correlation (ρ = .91,  = 0.00) existed between indoor and outdoor fine particulate matter mass concentration measurements. A direct relationship between indoor and outdoor PM mass concentrations was observed during this study, suggesting that elevated fine particulate matter concentrations due to wildfire smoke could be a concern in the indoor work environment; however the current study determined that the use of a portable air cleaner can substantially decrease fine particulate matter concentrations even in an active office setting.

Download full-text PDF

Source
http://dx.doi.org/10.1080/15459624.2020.1722314DOI Listing

Publication Analysis

Top Keywords

fine particulate
28
particulate matter
28
portable air
20
air cleaner
20
mass concentrations
12
indoor outdoor
12
office setting
8
wildfire smoke
8
relationship indoor
8
outdoor mass
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!