Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Field switching ion shutters allow generating short ion packets with high ion densities by first ionizing for several milliseconds in a field-free ionization region and then quickly pushing the entire ion population out into the drift region. Thus, they are an excellent choice for compact ion mobility spectrometers with both high resolving power and low limits of detection. Here, we present an improved setup, named the extended field switching ion shutter. By generating a second field-free region between the ionization region and the drift region, shielding of the ionization region is significantly improved, even when using grids with higher optical transparency to improve ion transmission into the drift region. Furthermore, it is shown that under certain conditions, ion transmission through multiple grids in series can even surpass transmission through a single grid of the same transparency. For the studied ions, the signal intensity at low concentrations increases by approximately a factor of 7 to 9 for protonated monomers, 10 to 14 for proton-bound dimers, and 25 for the proton-bound 1-octanol trimer compared to the classical field switching shutter. However, due to the nonlinear response for ions containing multiple analyte molecules, the limits of detection improve only by a factor of 3 to 4 for proton-bound dimers and 3 for the proton-bound 1-octanol trimer. Nevertheless, this still leads to single-digit ppt limits of detection for protonated monomers and hundred ppt limits of detection for proton-bound dimers measured for a series of ketones. However, for the most intense peaks such as the reactant ion peak, a significant loss of resolving power by a factor of up to 1.4 was observed due to Coulomb repulsion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.9b04259 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!