Arhinia (congenital absence of the nose) is a congenital rare disease, which has been reported in less than 60 cases in the literature. It consists of the absence of external nose, nasal cavities and olfactory apparatus and is generally associated with midline defects, microphthalmia, blepharophimosis and hypotelorism. Aesthetic problems as well as associated functional anomalies can potentially impact on the development and interpersonal relationships of the child at a later stage in life. Arhinia requires extensive management in early life in order to ensure airway patency and protection by means of tracheostomy, and to allow adequate pharyngeal and feeding function to the child. Aesthetic issues are managed with reconstructive surgery or an external prosthesis. There is no previous description in Literature of internal prosthetic devices used to sequentially shape soft tissues in complex reconstruction. We present an example of design and manufacturing of a bespoke nose implant produced by means of 3D printing and directly assessed on-table by means of 3D surface scanning.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7061611PMC
http://dx.doi.org/10.1016/j.jpra.2019.05.002DOI Listing

Publication Analysis

Top Keywords

design manufacturing
8
manufacturing patient-specific
4
patient-specific nasal
4
nasal implant
4
implant congenital
4
congenital arhinia
4
arhinia case
4
case report
4
report arhinia
4
arhinia congenital
4

Similar Publications

Electromagnetic Wavefront Engineering by Switchable and Multifunctional Kirigami Metasurfaces.

Nanomaterials (Basel)

January 2025

Shanghai Engineering Research Centre of Ultra Precision Optical Manufacturing, Department of Optical Science and Engineering, School of Information Science and Technology, Fudan University, Shanghai 200433, China.

Developing switchable and multifunctional metasurfaces is essential for high-integration photonics. However, most previous studies encountered challenges such as limited degrees of freedom, simple tuning of predefined functionality, and complicated control systems. Here, we develop a general strategy to construct switchable and multifunctional metasurfaces.

View Article and Find Full Text PDF

Nanocomposites for Multifunctional Sensors: A Comprehensive Bibliometric Exploration.

Nanomaterials (Basel)

December 2024

Technology, Instruction and Design in Engineering and Education Research Group (TiDEE.rg), Catholic University of Ávila, C/Canteros s/n, 05005 Ávila, Spain.

Multifunctional nanocomposites have become critical components in advancing sensing technologies, owing to their exceptional integration of mechanical, electrical, thermal, and optical properties. The research landscape of nanocomposites for sensing applications from 2002 to 2024 is examined in this bibliometric review. It identifies key trends, influential works, prominent research areas, and global collaboration networks.

View Article and Find Full Text PDF

Aim: The aim of this systematic review was to evaluate the effect of build orientation on the mechanical and physical properties of additively manufactured resin using digital light processing (DLP).

Background: The properties of 3D-printed materials are influenced by various factors, including the type of additive manufacturing (AM) system and build orientation. There is a scarcity of literature on the effect of build orientation on the mechanical and physical properties of additively manufactured resins using DLP technology in dentistry.

View Article and Find Full Text PDF

Interchangeability of Contemporary Semi-adjustable Articulators Used Over Time: An Study.

J Contemp Dent Pract

September 2024

Department of Preventive and Restorative Dentistry, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, United States.

Aim: The purpose of this study is to investigate the interchangeability of newly acquired, short-term used, and long-term used semi-adjustable articulators.

Materials And Methods: Metal analogs of partially dentate maxillary and mandibular arches were mounted on twelve semi-adjustable Stratos 300 articulators, divided into three groups based on usage over time: New, short-term used (<2 years), long-term used (>2 years) articulators. Each articulator was calibrated according to manufacturer guidelines, ensuring consistency.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!