This report presents an unusual case of instrumentation failure after posterior fixation of a C2 fracture and reviews currently available treatment alternatives. The patient, a 53-year-old female, initially presented to the emergency department at an outside facility with acute alcohol intoxication and acute neck pain following a fall from a ladder. CT demonstrated bilateral C2 pars fractures and unstable posteroinferior displacement of the posterior elements. She underwent an emergent C2 open-reduction internal fixation (ORIF) at the outside facility with 3.5 mm polyaxial synapse pedicle screws (DePuy Synthes, Switzerland). There were no known complications and the patient was discharged. Two years after the index operation, cervical CT scan at a different facility revealed that although the fracture was fully healed, bilateral tulip caps had detached from the pedicle screw heads at C2. All implants were removed without postoperative complications. Industry review of alternate lag screws approved for the cervical spine demonstrated that there is not currently an ideal implant for fixation of C2 fractures without fusion. Cannulated trauma screws, which are low profile and would have avoided the instrumentation failure seen here, are not currently FDA approved for the cervical spine.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7060438 | PMC |
http://dx.doi.org/10.1155/2020/5824383 | DOI Listing |
Medicina (Kaunas)
January 2025
Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu 42601, Republic of Korea.
A basicervical femoral fracture is a relatively uncommon type of proximal femoral fracture. However, as the proportion of proximal femoral fractures rises in conjunction with the aging of society, the absolute number of patients with basicervical femoral fractures is also increasing. Nevertheless, the optimal surgical methods for the treatment of basicervical femoral fractures remain a topic of debate.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedics and Traumatology, Karabük University, Karabük 78050, Turkey.
The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.
View Article and Find Full Text PDFMedicina (Kaunas)
December 2024
Department of Orthopedic Surgery, Ajou University School of Medicine, Suwon 16499, Republic of Korea.
Valgus-impacted femoral neck fractures (OTA 31B1.1 and 31B1.2) are considered stable fractures with favorable outcomes compared to displaced fractures.
View Article and Find Full Text PDFBeijing Da Xue Xue Bao Yi Xue Ban
February 2025
Department of Nephrology, Peking University People's Hospital, Beijing 100044, China.
Objective: Peritoneal dialysis(PD)-associated peritonitis is a common and major complication of PD and the most common cause of technical failure of PD. The presence of bacterial biofilm may be an important factor leading to refractory or recurrence of peritonitis. To investigate the formation and characteristics of bacterial biofilms on PD catheters after peritonitis-associated catheter removal.
View Article and Find Full Text PDFBeijing Da Xue Xue Bao Yi Xue Ban
February 2025
Second Clinical Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100101, China.
Objective: To compare the cyclic fatigue resistance of nickel-titanium files made by 3 new heat treatment in simulated S-shaped root canals at different temperatures.
Methods: Gold heat-treated nickel-titanium files TruNatomy (25 mm, tip size 26#/0.04) and ProTaper Gold (25 mm, tip size 25#/0.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!