Objectives: The physiological determinants of left ventricular (LV) mechanical dispersion (MD) are not fully explored. We aimed to investigate the impact of afterload reduction and changes in ventricular conduction on LV MD after transcatheter aortic valve implantation (TAVI).

Methods: Patients with severe aortic stenosis (AS) were examined in a prospective, repeated measures observational cohort study before and after an uncomplicated transfemoral TAVI in a single tertiary centre. LV MD was assessed by speckle tracking echocardiography. Valvulo-arterial impedance (ZVA) was used as a measure of global afterload.

Results: We included 140 consecutive patients (83±8 years old, 49% women, logistic EuroSCORE 16±10) with severe AS (valve area 0.7±0.2 cm, mean transvalvular gradient 54±18 mm Hg) and a relatively preserved LV ejection fraction (52%±11%). After TAVI, we observed favourable changes in transvalvular gradients and ZVA in all patients. Compared with baseline, postprocedural MD was significantly lower in 108 patients with unchanged ventricular conduction (55±17 ms vs 51±17 ms, p=0.02) and higher in 28 patients with TAVI-induced left bundle branch block (51±13 ms vs 62±19 ms, p≤0.001). During 22±9 months observation, 22 patients died. Postprocedural MD was associated with mortality in a univariate Cox regression model (HR=1.24 (1.01-1.52), p<0.04, per 10 ms increase).

Conclusions: Isolated afterload reduction was associated with reduction of MD, while concomitant impairment of ventricular conduction resulted in a more pronounced MD after TAVI, indicating that loading conditions and conduction should be considered when evaluating MD. A pronounced postprocedural LV MD was associated with mortality.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7046982PMC
http://dx.doi.org/10.1136/openhrt-2019-001199DOI Listing

Publication Analysis

Top Keywords

transcatheter aortic
8
aortic valve
8
valve implantation
8
mechanical dispersion
8
ventricular conduction
8
patients
6
impact transcatheter
4
implantation mechanical
4
dispersion objectives
4
objectives physiological
4

Similar Publications

Transfemoral transcatheter aortic valve Replacement (TAVR) has become the standard therapy for patients with severe aortic stenosis in patients over 75 years old in Europe or 65 years old in the United States, regardless of the surgical risk. Furthermore, iterations of existing transcatheter aortic valves (TAVs), as well as devices with novel concepts, have provided substantial improvements with respect to the limitations of previous-generation devices. Hence, treatment of a broader spectrum of patients has become feasible, and a sophisticated selection of the appropriate TAV tailored to patients' anatomy and comorbidities is now possible.

View Article and Find Full Text PDF

Background: A staging system based on cardiac damage for severe aortic stenosis (AS) has been validated for prognosis prediction following transcatheter aortic valve replacement (TAVR). Our study aims to investigate whether TAVR can lead to changes in cardiac damage shortly after the procedure and how these changes impact prognosis.

Method: Patients in this retrospective cohort study were classified into five stages (0-4) before TAVR based on the echocardiographic findings of cardiac damage.

View Article and Find Full Text PDF

ECMO in the Cardiac Catheterization Lab-Patient Selection Is Key.

J Cardiovasc Dev Dis

December 2024

Department of Cardiothoracic and Vascular Surgery, Montefiore Medical Center, Bronx, NY 10467, USA.

The use of extracorporeal membrane oxygenation (ECMO) has emerged as a rescue intervention for hemodynamically unstable patients and prophylactic intraprocedural hemodynamic support in the cardiac catheterization laboratory. The prompt initiation of ECMO provides immediate hemodynamic support and allows for the completion of bridging and/or life-saving interventions. However, there are no clinical practice guidelines for the use of extracorporeal support in this area.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis and raphe-type bicuspid aortic valve (BAV) is still associated with poor outcomes in terms of increased risk of paravalvular regurgitation, stroke, and permanent pacemaker implantation. There is no definitive consensus on the optimal sizing method for prosthesis selection in this setting. The LIRA method is a supra-annular tailored sizing method specifically designed for bicuspid anatomy that might increase accuracy of prosthesis choice in BAV patients and improve TAVR outcomes.

View Article and Find Full Text PDF

Objective: Percutaneous vegetation debulking has been reported to treat tricuspid valve infective endocarditis (TVIE), but data on feasibility compared with conventional surgical strategies are limited. We aimed to compare short-term outcomes of suction debulking with partial venovenous bypass to conventional open surgery in this population.

Methods: This was a single-center, retrospective study that included all patients with isolated TVIE who underwent suction debulking with partial venovenous bypass or tricuspid valve surgery between January 2010 and December 2022.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!