Background: The aim of this study was to evaluate the accuracy of mitral regurgitation (MR) volume quantified on three-dimensional (3D) color Doppler transesophageal echocardiography (TEE) using new semiautomated software compared with conventional two-dimensional (2D) proximal isovelocity surface area (PISA) transthoracic echocardiography (TTE) and TEE and cardiac magnetic resonance imaging (CMR).
Methods: Fifty-one patients (mean age, 63 ± 16 years; 35 men) prospectively underwent TTE, TEE, and CMR for MR evaluation. Regurgitant volume (RVol) by 3D MR flow quantification was compared with 2D TTE, TEE, and CMR, and the accuracy of evaluation of severe MR by 3D MR flow quantification was compared against guideline criteria by TEE.
Results: Twenty-nine patients had severe MR, 16 had moderate MR, and six had mild MR. Three-dimensional MR flow quantification was feasible in all patients, including prolapse (n = 37), restriction (n = 9), functional MR (n = 5), and eccentric or multiple jects (n = 41). RVol on 3D MR flow quantification correlated well with RVol on 2D PISA TTE (interclass correlation coefficient [ICC] = 0.75, P < .001), quantitatively estimated RVol (ICC = 0.74, P < .001), and 2D PISA TEE (ICC = 0.79, P < .001). Three-dimensional MR flow quantification agreed better with CMR (ICC = 0.86, P < .001) than did RVol on 2D PISA TTE (ICC = 0.66, P < .001) and 2D PISA TEE (ICC = 0.69, P < .001), with narrower limits of agreement on Bland-Altman analysis. Three-dimensional MR flow quantification had high accuracy for diagnosing severe MR using TEE (area under the curve = 0.85, 95% CI 0.74-0.96, P < .001) or CMR (area under the curve = 0.95; 95% CI, 0.89-1.00; P < .001) as the criterion.
Conclusions: The new software enabled semiautomated 3D MR flow quantification in complex MR with multiple and eccentric jets and showed better agreement with CMR than 2D PISA TTE or TEE, suggesting that this method is more accurate than conventional 2D PISA TTE and TEE.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.echo.2019.10.013 | DOI Listing |
J Chromatogr B Analyt Technol Biomed Life Sci
December 2024
Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, Cape Town, South Africa. Electronic address:
A robust LC-MS/MS method was developed to quantify total and unbound doravirine in plasma samples from patients receiving daily doses of 100 mg doravirine, in combination with lamivudine and tenofovir disoproxil fumarate, in a phase 3 clinical trial. The trial is ongoing, and sample analysis is planned to commence once all samples have been collected. The method was validated to quantify both total and unbound doravirine using a single calibration curve.
View Article and Find Full Text PDFFluids Barriers CNS
January 2025
Medical Image Processing Department, CHU Amiens-Picardie University Hospital, Amiens, France.
Background: The pressure gradient between the ventricles and the subarachnoid space (transmantle pressure) is crucial for understanding CSF circulation and the pathogenesis of certain neurodegenerative diseases. This pressure can be approximated by the pressure difference across the aqueduct (ΔP). Currently, no dedicated platform exists for quantifying ΔP, and no research has been conducted on the impact of breathing on ΔP.
View Article and Find Full Text PDFCardiovasc Eng Technol
January 2025
Transonic Systems Inc., 34 Dutch Mill Road, Ithaca, New York, 14850, USA.
Purpose: Over time, transit time flow measurement (TTFM) has proven itself as a simple and effective tool for intra-operative evaluation of coronary artery bypass grafts (CABGs). However, metrics used to screen for possible technical error show considerable spread, preventing the definition of sharp cut-off values to distinguish between patent, questionable, and failed grafts. The simulation study presented in this paper aims to quantify this uncertainty for commonly used patency metrics, and to identify the most important physiological parameters influencing it.
View Article and Find Full Text PDFBiomed Chromatogr
February 2025
School of Chemistry & Physics, College of Agriculture, Engineering & Science, Westville Campus, University of KwaZulu-Natal, Durban, South Africa.
A new selective and sensitive high-performance liquid chromatography (HPLC) method was developed for the quantification of potential impurities in fluoxetine hydrochloride. Chromatographic separation was achieved on an end-capped octadecylsilyl silica gel (Gemini-C18 150 mm × 4.6 mm, 3.
View Article and Find Full Text PDFMethods Mol Biol
January 2025
Department of Biological Sciences, University of North Texas, Denton, TX, USA.
In our laboratory, we study thrombopoiesis and hemostasis using zebrafish as a model organism to unravel the mechanisms of differentiation and development of thrombocytes. We have shown in our earlier work that thrombocytes are functional equivalents of platelets and have transcriptional machinery similar to megakaryocytes. We recently found evidence that hox genes play a role in their development.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!