This paper attempts to systematise all published experimental results for the dose reduction factor (DRF) offered by leaded eyewear on clinicians performing interventional procedures. We aim to present a comprehensive analysis of the issue and a comparison of the various equipment models at different exposure geometries. The main purpose of the paper is, however, to clarify the best choice for the DRF within the possible diverse contexts and approaches to eye lens dose assessment. Evidence has been obtained that the lowest estimates of DRF are associated with larger scatter incidence angles and that, except for the slightly better performance exhibited by wraparound eyeglasses, there is no real distinction between the DRFs for the different equipment categories. The dataset as a whole confirms that, when measurements for the concerned eyewear model and irradiation conditions are unattainable, assuming DRF = 2 represents an adequately conservative choice. Nonetheless, this value includes only 17% of all results from the literature, whereas their histogram follows a distribution skewed towards higher values, represented by a median equal to 5. Therefore, if more realistic dose reconstructions are necessary, such as for purposes of epidemiological investigations or compensation decisions, the adoption of this central tendency index appears to be more reasonable. The complexity of characterising the DRF behaviour as a function of the various exposure factors reinforces the consideration of a statistical approach to eye lens dose assessment as a viable alternative. In this perspective, assuming for DRF a lognormal distribution with parameters [Formula: see text] and [Formula: see text] which has been verified to satisfactorily approximate the literature data distribution, should be deemed to be an appropriate option.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6498/ab7d8c | DOI Listing |
Small Methods
December 2024
Institute of Translational Medicine, Nanjing Drum Tower Hospital, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.
Colored contact lenses have gained popularity among young individuals owing to their ability to alter the appearance of the wearer's eyes. However, conventional lenses containing chemical dyes are susceptible to detachment of the pigment layer, which can lead to corneal damage. In this research, a novel cellulose-based structural color contact lens (SCCL) is presented that enhances aesthetic appeal via a cholesteric liquid crystal (CLC) layer.
View Article and Find Full Text PDFClin Ophthalmol
December 2024
Department of Ophthalmology, Visual and Anatomical Sciences, Kresge Eye Institute/Wayne State University School of Medicine, Detroit, MI, USA.
Purpose: To evaluate the outcomes of scleral-fixated intraocular lenses (IOLs) implanted using either Yamane technique or Gore-Tex suture fixation, in comparison to intracapsular lens fixation, and to assess the efficacy of various lens formulas in achieving predicted refractive targets.
Patients And Methods: This study included 45 eyes from 44 patients with scleral-fixated IOLs, comprising 37 Yamane eyes and 8 Gore-Tex eyes. Preoperative refractive predictions from various formulae were compared with final postoperative refraction.
Cureus
November 2024
Ophthalmology, Moorfields Eye Hospital, London, GBR.
We report a case of spontaneous total iris avulsion that occurred during corneal wound hydration following an uneventful phacoemulsification procedure. An 86-year-old woman underwent cataract surgery on her right eye, during which a single-piece acrylic intraocular lens (Bausch and Lomb Akreos Adapt Advanced Optics, Bausch and Lomb Incorporated, Rochester, NY, USA) was implanted in the bag, and the viscoelastic material was removed. During corneal wound hydration, total iris avulsion was observed, with the iris prolapsing out of the anterior chamber through the main wound.
View Article and Find Full Text PDFEye Vis (Lond)
December 2024
Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China.
Over the past two decades, both suture and sutureless techniques for scleral fixation of intraocular lenses have seen significant advancement, driven by improvements in methodologies and instrumentation. Despite numerous reports demonstrating the effectiveness, safety, and superiority of these techniques, each approach carries with it its own drawbacks, including an elevated risk of certain postoperative complications. This article delves into various surgical techniques for scleral fixation of posterior chamber intraocular lenses, discussing their procedural nuances, benefits, drawbacks, postoperative complications, and outcomes.
View Article and Find Full Text PDFOcul Surf
December 2024
AZURA Ophthalmics, Tel-Aviv, Israel.
Background: Contact lens discomfort (CLD) is a common problem for CL wearers, and patients with CLD often have changes in meibomian gland function and structure. In a Phase 2 trial AZR-MD-001 0.5% (AZR) ophthalmic ointment improved meibomian gland dysfunction (MGD) in non-lens wearers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!