A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effectiveness and safety of EUS-guided choledochoduodenostomy using lumen-apposing metal stents (LAMS): a systematic review and meta-analysis. | LitMetric

Background: Endoscopic ultrasound-guided choledochoduodenostomy (CDD) is emerging as an alternative technique for biliary drainage in patients who fail conventional endoscopic retrograde cholangiopancreatography (ERCP). The lumen-apposing metal stents (LAMS) are being increasingly used for CDD. We performed a systematic review and meta-analysis to evaluate the effectiveness and safety of CDD using LAMS.

Methods: We performed a systematic search of multiple databases through May 2019 to identify studies on CDD using covered self-expanding metal stents. Pooled rates of technical success, clinical success, adverse events, and recurrent jaundice associated with CDD using LAMS were estimated. A subgroup analysis was performed based on use of LAMS with electrocautery-enhanced delivery system (EC-LAMS).

Results: Seven studies on CDD using LAMS (with 284 patients) were included in the meta-analysis. Pooled rates of technical and clinical success (per-protocol analysis) were 95.7% (95% CI 93.2-98.1) and 95.9% (95% CI 92.8-98.9), respectively. Pooled rate of post-procedure adverse events was 5.2% (95% CI 2.6-7.9). Pooled rate of recurrent jaundice was 8.7% (95% CI 4.5-12.8). On subgroup analysis of CDD using EC-LAMS (5 studies with 201 patients), the pooled rates of technical and clinical success (per-protocol analysis) were 93.8% (95% CI 90.4-97.1) and 95.9% (95% CI 91.9-99.9), respectively. Pooled rate of post-procedure adverse events was 5.6% (95% CI 1.7-9.5). Pooled rate of recurrent jaundice was 11.3% (95% CI 6.9-15.7). Heterogeneity (I) was low to moderate in the analyses.

Conclusion: CDD using LAMS/EC-LAMS is an effective and safe technique for biliary decompression in patients who failed ERCP. Further studies are needed to assess CDD using LAMS as primary treatment modality for biliary obstruction.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-020-07484-wDOI Listing

Publication Analysis

Top Keywords

pooled rate
16
metal stents
12
pooled rates
12
rates technical
12
clinical success
12
adverse events
12
recurrent jaundice
12
cdd lams
12
cdd
9
effectiveness safety
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!