A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prospective evaluation of the setup errors and its impact on safety margin for cervical cancer pelvic conformal radiotherapy. | LitMetric

Aim: The primary objective was to assess set-up errors (SE) and secondary objective was to determine optimal safety margin (SM).

Background: To evaluate the SE and its impact on the SM utilizing electronic portal imaging (EPI) for pelvic conformal radiotherapy.

Material And Methods: 20 cervical cancer patients were enrolled in this prospective study. Supine position with ankle and knee rest was used during CT simulation. The contouring was done using consensus guideline for intact uterus. 50 Gy in 25 fractions were delivered at the isocenter with ≥95% PTV coverage. Two orthogonal (Anterior and Lateral) digitally reconstructed radiograph (DRR) was constructed as a reference image. The pair of orthogonal [Anterior-Posterior and Right Lateral] single exposure EPIs during radiation was taken. The reference DRR and EPIs were compared for shifts, and SE was calculated in the X-axis, Y-axis, and Z-axis directions.

Results: 320 images (40 DRRs and 280 EPIs) were assessed. The systematic error in the Z-axis (AP EPI), X-axis (AP EPI), and Y-axis (Lat EPI) ranged from -12.0 to 11.8 mm, -10.3 to 7.5 mm, and -8.50 to 9.70 mm, while the random error ranged from 1.60 to 6.15 mm, 0.59 to 4.93 mm, and 1.02 to -4.35 mm. The SM computed were 7.07, 6.36, and 7.79 mm in the Y-axis, X-axis, and Z-axis by Van Herk's equation, and 6.0, 5.51, and 6.74 mm by Stroom's equation.

Conclusion: The computed SE helps defining SM, and it may differ between institutions. In our study, the calculated SM was approximately 8 mm in the Z-axis, 7 mm in X and Y axis for pelvic conformal radiotherapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7049598PMC
http://dx.doi.org/10.1016/j.rpor.2020.02.006DOI Listing

Publication Analysis

Top Keywords

pelvic conformal
12
safety margin
8
cervical cancer
8
conformal radiotherapy
8
prospective evaluation
4
evaluation setup
4
setup errors
4
errors impact
4
impact safety
4
margin cervical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!