Here we present a rare combination of aortobronchial fistula and endograft infection after repeat endovascular aortic repair. Device retention, debridement and negative pressure wound therapy, in combination with suppressive antimicrobial therapy, led to satisfactory control of infection until the patient died due to another complication. The combination of an aortobronchial fistula and endograft infection has never been described before. This present case should encourage and show clinicians the importance of an interdisciplinary approach in highly difficult clinical courses.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7059411 | PMC |
http://dx.doi.org/10.1136/bcr-2019-229924 | DOI Listing |
Objective: The aim of the study was to summarize epidemiologic data about aortobronchial fistulas and compare outcomes (mortality, recurrence, re-operation) of open, staged, and endovascular repair of aortobronchial fistula.
Methods: A systematic literature review was conducted to identify eligible studies published between January of 1999 and December of 2019. The Cochrane Library, PubMed and Scopus databases were used as search engines.
JTCVS Tech
October 2024
Department of Cardiothoracic Surgery, Emory University Hospitals, Atlanta, Ga.
J Vasc Interv Radiol
January 2025
Department of Radiology, Mie University Hospital, Tsu, Mie, Japan.
Purpose: To investigate the effectiveness and safety of thoracic endovascular aortic repair (TEVAR) for infectious aortic diseases.
Materials And Methods: Patients who underwent TEVAR for infectious aortic diseases including infected thoracic aortic aneurysm, aortobronchial fistula (ABF), and aortoenteric fistula from December 2011 to October 2022 at 4 institutions were retrospectively studied. The primary outcome of the study was overall survival, whereas the secondary outcome was comprehensive adverse events.
Cardiovasc Pathol
November 2024
Department of Pathology and Immunology, Washington University in St. Louis School of Medicine, 660 South Euclid Avenue, St. Louis, MO 63110, USA. Electronic address:
J Vasc Surg Cases Innov Tech
December 2024
Division of Vascular Diseases and Surgery, Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, OH.
Thoracic endovascular aortic repair (TEVAR) enables rapid and effective treatment of life-threatening aortic injuries. The occurrence of long-term complications from TEVAR and their management is ill-defined in young patients. This report describes a complex case of a 38-year-old male patient who underwent staged interventions for different acute pathologies instigated by blunt thoracic spinal trauma.