Introduction: Osseointegration are often suffering from oral conditions, especially, the micro gap at the implant-abutment connection represents a site for bacterial plaque aggregation, leading to increased inflammatory cells and causing peri-implantitis.

Aim: The aim of this narrative review was to describe the different kinds of implant-abutment connections and their ability to reduce bacterial leakage and thus prevent peri-implantitis.

Materials And Methods: The following databases were consulted: Pubmed, Scopus, Cochrane Library, and Research gate and a total of 528 articles were found. After reading the abstract and titles, 473 items were excluded. The remaining articles (n = 55) were assessed for full-text eligibility. Thirty-three studies were included in the review.

Results And Conclusions: We selected 22 clinical trials and 11 reviews, examining a total sample of 2110 implants. From the review, it was clear that there exists a relationship between the implant-abutment interface and bacterial leakage. All the connections presented an amount of micro-gap and bacterial micro-leakage, though conical and mixed connection systems seemed to behave better. Moreover, both connections seemed to have a better load distribution and the mixed system also had anti-rotational properties which are very useful during the positioning of the prosthesis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085009PMC
http://dx.doi.org/10.3390/ma13051131DOI Listing

Publication Analysis

Top Keywords

implant-abutment connection
8
narrative review
8
bacterial leakage
8
impact implant-abutment
4
connection clinical
4
clinical outcomes
4
outcomes microbial
4
microbial colonization
4
colonization narrative
4
review introduction
4

Similar Publications

Molding Quality and Biological Evaluation of a Two-Stage Titanium Alloy Dental Implant Based on Combined 3D Printing and Subtracting Manufacturing.

ACS Omega

December 2024

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration & National Clinical Research Center for Oral Diseases & Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an 710032, Shaanxi, P. R. China.

Metal 3D printing has been used in the manufacturing of dental implants. Its technical advantages include high material utilization and the capacity to form arbitrarily complex structures. However, 3D printing alone is insufficient for manufacturing two-stage titanium implants due to the limited precision in printing titanium alloy parts.

View Article and Find Full Text PDF

3D analysis of soft tissue dimensional changes after dental implant placement with butt-joint vs. conical connection: a 12-month randomized control trial.

Int J Implant Dent

December 2024

Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt- Universität zu Berlin, Aßmannshauser Str. 4-6, 14197, Berlin, Germany.

Purpose: to quantify the soft tissue dimensional changes after single-gap implant placement, during healing abutment and crown delivery phase for butt-joint and conical implant-abutment connection type.

Methods: forty patients were enrolled in the study and received randomly allocated implants with butt-joint and conical implant-abutment connection type. A standard healing abutment was placed after 6 months for two weeks.

View Article and Find Full Text PDF

Purpose: To assess the effect of healthy and inflammatory conditions and the presence of F anions on the galvanic coupling between the root surface and titanium abutments of commercially available titanium implants MATERIALS AND METHODS: Eight pairs of three dental root-abutment couples (BEGO, MIS, NOBEL) were exposed to a neutral (pH=7.4) (HE) and an acidic (pH=4.0) (IN) phosphate buffer solution (PBS) simulating healthy and inflammatory conditions respectively.

View Article and Find Full Text PDF
Article Synopsis
  • - The study aimed to determine if using an anaerobic adhesive on abutment screws impacts the stability of dental implants, specifically comparing external hexagon (EHC) and conical connections (CC).
  • - Twenty implants were tested using a digital torque meter and resonance frequency measurements to gauge implant stability, revealing that ISQ values were lower after applying the adhesive.
  • - Results indicated that while the adhesive reduced ISQ readings, its curing time had no additional effect on the stability, suggesting that comparisons of ISQ values between adhesive-treated and untreated screws are invalid.
View Article and Find Full Text PDF

The geometry of implants plays a crucial role in the success of All-on-Four treatments for the lower jaw. This study builds upon prior research by evaluating the biomechanical performance of implant-supported prostheses in full-arch fixed dental restorations, specifically focusing on different implant lengths and connection types in cases of mild atrophic resorption of the mandible. Four groups were analyzed using finite element analysis (FEA): We utilized 13 or 18 mm posterior 17-degree tilting implants, each paired with two kinds of abutment connections.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!