Purpose: Commercially available systems for ion beam reference dosimetry in water are mainly based on ionization chambers. In those systems, a large number of small detectors are typically arranged in a two-dimensional (2D) array or matrix to achieve high spatial resolution (order of several millimeters) and large field coverage at the same time. The goal of this work was to investigate the reliability of a detector of superior spatial resolution to perform three-dimensional (3D) ionization measurements in carbon ion pencil beams.

Methods: The GEMPix is a small gaseous detector with a highly pixelated readout, consisting of a drift region (with 2.8 cm  × 2.8 cm  × 0.3 cm volume), three gas electron multipliers (GEMs) for signal amplification and four Timepix ASICs with 55 µm pixel pitch and a total of 262,144 pixels. An integrated system was designed and built, which consists of a commercial water phantom with a three-axis motorized arm, a reference large-area ionization chamber for signal normalization to the beam output and the GEMPix itself. Measurements at different depths in water have been performed at the Italian National Centre for Oncological Hadrontherapy (CNAO) with three carbon ion beam energies. Lateral beam profiles measured with the GEMPix at the shallowest depth were compared to those measured with radiochromic EBT3 films in air in the position of the reference ionization chamber. The Timepix readout was calibrated in energy by using one independent depth scan with carbon ions of 150 mm range. Bragg peak curves were also simulated using the Monte Carlo FLUKA code as a reference.

Results: Beam profiles measured with the GEMPix were smooth and showed similar shape and full width at half maximum when compared to those measured with radiochromic EBT3 films. Smooth, reproducible Bragg curves were obtained with statistical uncertainties of about 2%, matching FLUKA simulations of the Bragg curves within 15% for most data points. This difference is partially explained for the measurement with carbon ions of 150 mm range by a saturation effect in the GEMs. The high granularity of the readout allowed to produce 2D images of the deposited dose at different depths, as well as 3D data distributions.

Conclusions: This paper demonstrates the capability of the GEMPix detector to measure the 3D dose distribution of carbon ions in water for a clinical pencil beam reliably. In the future, the detector area will be increased to cover fields of scanned beams. Measurements at higher beam intensities and with protons are planned.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7384041PMC
http://dx.doi.org/10.1002/mp.14119DOI Listing

Publication Analysis

Top Keywords

carbon ion
12
carbon ions
12
integrated system
8
beam
8
ion beam
8
spatial resolution
8
ionization chamber
8
beam profiles
8
profiles measured
8
measured gempix
8

Similar Publications

Catalytic Enantioselective Nucleophilic Amination of α-Halo Carbonyl Compounds with Free Amines.

J Am Chem Soc

December 2024

Department of Chemistry and the Hong Kong Branch of Chinese National Engineering Research Centre for Tissue Restoration & Reconstruction, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR 999077, China.

Catalytic enantioselective substitution of the readily available racemic α-halo carbonyl compounds by nitrogen nucleophiles represents one of the most convenient and direct approaches to access enantioenriched α-amino carbonyl compounds. Distinct from the two available strategies involving radicals and enolate ions, herein we have developed a new protocol featuring an electronically opposite way to weaken/cleave the carbon-halogen bond. A suitable chiral anion-based catalyst enables effective asymmetric control over the key positively charged intermediates.

View Article and Find Full Text PDF

Tire Wear Particles Exposure Enhances Denitrification in Soil by Enriching Labile DOM and Shaping the Microbial Community.

Environ Sci Technol

December 2024

State Key Laboratory of Soil and Sustainable Agriculture, Changshu National Agro-Ecosystem Observation and Research Station, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008, China.

Tire wear particles (TWP) are emerging contaminants in the soil environment due to their widespread occurrence and potential threat to soil health. However, their impacts on soil biogeochemical processes remain unclear. Here, we investigated the effects of TWP at various doses and their leachate on soil respiration and denitrification using a robotized continuous-flow incubation system in upland soil.

View Article and Find Full Text PDF

Recently, ultra-high dose rate (> 40 Gy/s, uHDR; FLASH) radiation therapy (RT) has attracted interest, because the FLASH effect that is, while a cell-killing effect on cancer cells remains, the damage to normal tissue could be spared has been reported. This study aimed to compare the immune-related protein expression on cancer cells after γ-ray, conventionally used dose rate (Conv) carbon ion (C-ion), and uHDR C-ion. B16F10 murine melanoma and Pan02 murine pancreas cancer were irradiated with γ-ray at Osaka University and with C-ion at Osaka HIMAK.

View Article and Find Full Text PDF

Separation of valuable materials from spent lithium-ion battery based on granulation regulation.

Waste Manag

December 2024

National Engineering Research Center of Green Recycling for Strategic Metal Resources, Chemistry & Chemical Engineering Data Center, Chinese Academy of Sciences, Institute of Process Engineering, Beijing 100190, China; University of Chinese Academy of Sciences, Beijing 100190, China. Electronic address:

Recycling of spent lithium-ion batteries has attracted worldwide attention to ensure sustainability of electric vehicle industry. Pretreatment as an essential step for recycling of spent LIBs is critical to ensure the recovery efficiency and quality of black mass which is used for further materials regeneration. Usually, high temperature pyrolysis, at around 600 °C is required during the pretreatment to achieve effective separation of the black mass that is binding on aluminium foils with polyvinylidene fluoride binder.

View Article and Find Full Text PDF

Superior selectivity for efficiently reductive degradation of hydrophobic organic pollutants in strongly competitive systems.

J Hazard Mater

December 2024

Department of Civil, Construction and Environmental Engineering, San Diego State University, 5500 Campanile Drive, San Diego, CA 92182, USA.

Highly toxic halo-/nitro-substituted organics, often in low concentrations and with high hydrophobicity, make it difficult to obtain electrons for reduction when strongly electron-competing substances (e.g., O, H/HO, NO) coexist.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!