Temporal Super-resolution of Ultrasound Imaging Using Matrix Completion.

Ultrason Imaging

Rajaie Cardiovascular, Medical & Research Center, Tehran, Islamic Republic of Iran.

Published: May 2020

The temporal super-resolution of the dynamic ultrasound imaging, a means to observe rapid heart movements, is considered an important subject in medical diagnosis of cardiac conditions. Here, a new technique based on the acquisition scheme using the matrix completion (MC) theory is offered for the temporal super-resolution of the two-dimensional (2D) and three-dimensional (3D) ultrasound imaging. MC mentions the problem of completing a low-rank matrix when only a subset of its elements can be observed. Here, the lower scan lines are acquired. Whereby, the proposed method uses temporal and spatial information of the radio frequency (RF) image sequences for the reconstruction of skipped RF lines. This is performed using the construction of the MC images and then reconstruction of them by the MC theory. The results of the proposed method are compared with the compressive sensing (CS) reconstruction methods. The qualitative and quantitative evaluations of 2D and 3D data demonstrate that in the proposed method, which uses the spatial and temporal relation of RF images and the MC theory, the reconstruction is more accurate, and the reconstruction error is lower. The computational complexity of this method is very low. It also does not require hardware adjustments. Therefore, it can be easily implemented in current ultrasound-imaging devices with the frame-rate enhancement. For instance, the frame rate up to two times the original sequence is feasible using the proposed methods, while root mean square error is decreased by about 35% and 30% for 2D and 3D data, respectively, compared with the CS reconstruction method.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0161734620910163DOI Listing

Publication Analysis

Top Keywords

temporal super-resolution
12
ultrasound imaging
12
proposed method
12
matrix completion
8
reconstruction
6
temporal
5
method
5
super-resolution ultrasound
4
imaging matrix
4
completion temporal
4

Similar Publications

A long-standing goal of neuroimaging is the non-invasive volumetric assessment of whole brain function and structure at high spatial and temporal resolutions. Functional ultrasound (fUS) and ultrasound localization microscopy (ULM) are rapidly emerging techniques that promise to bring advanced brain imaging and therapy to the clinic with the safety and low-cost advantages associated with ultrasound. fUS has been used to study cerebral hemodynamics at high temporal resolutions while ULM has been used to study cerebral microvascular structure at high spatial resolutions.

View Article and Find Full Text PDF

Caliber of sensory axons in vivo varies spatially and temporally and is influenced by the cellular microenvironment.

bioRxiv

December 2024

Department of Cell, Molecular, and Developmental Biology, University of California, Los Angeles, Los Angeles, California 90095, USA.

Cell shape is crucial to cell function, particularly in neurons. The cross-sectional diameter, also known as caliber, of axons and dendrites is an important parameter of neuron shape, best appreciated for its influence on the speed of action potential propagation. Most studies of axon caliber focus on cell-wide regulation and assume that caliber is static.

View Article and Find Full Text PDF

Enhancing space-time video super-resolution via spatial-temporal feature interaction.

Neural Netw

December 2024

College of Electronic and Information Engineering, Tongji University, China; Shanghai Institute of Intelligent Science and Technology, Tongji University, China. Electronic address:

The target of space-time video super-resolution (STVSR) is to increase both the frame rate (also referred to as the temporal resolution) and the spatial resolution of a given video. Recent approaches solve STVSR using end-to-end deep neural networks. A popular solution is to first increase the frame rate of the video; then perform feature refinement among different frame features; and at last, increase the spatial resolutions of these features.

View Article and Find Full Text PDF

Tracking Single Kinesin in Live Cells Using MINFLUX.

Methods Mol Biol

December 2024

European Molecular Biology Laboratory, Cell Biology and Biophysics, Heidelberg, Germany.

MINFLUX is a super-resolution fluorescence microscopy technique that enables single-molecule tracking in live cells at a single-nanometer spatial and sub-millisecond temporal resolution. This chapter describes a method for tracking fluorescently labeled human kinesin-1 in live cells using MINFLUX and analyzing kinesin stepping dynamics.

View Article and Find Full Text PDF

Nighttime light (NTL) data is recognized as a reliable proxy for measuring the scope and intensity of human activity, finding wide application in studies such as urbanization monitoring, socioeconomic estimation, and ecological environment assessment. However, the substantial discrepancies and limited temporal coverage of existing NTL datasets have constrained their potential for long-term research applications. To address this, a Nighttime Light U-Net super-resolution network is proposed for the cross-sensor calibration between the Defense Meteorological Satellite Program-Operational Linescan System (DMSP-OLS) NTL data and the Suomi National Polar-Orbiting Partnership-Visible Infrared Imaging Radiometer Suite (NPP-VIIRS) NTL data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!