Objective:  Two different methods for fine needle aspiration biopsy (FNAB) of thyroid nodules (multi-pass conventional smear, MPCS; single-pass liquid-based cytology, SPLBC) were evaluated regarding the magnitude of nondiagnostic/unsatisfactory sampling ratio, and basic demographic and ultrasonographic (USG) factors to predict such outcome.

Methods:  One thousand FNAB patients were retrospectively assessed. Of them, 517 nodules were evaluated with the conventional smear method, and the rest were evaluated with liquid-based cytology method using the Bethesda System for Reporting Thyroid Cytopathology. FNAB technique had certain procedural differences for both pathological methods. For conventional smear, a modified "needle-only" technique with three independent passes was performed, whereas a single pass was used for liquid-based cytology. The reduction of nondiagnostic/unsatisfactory results constituted the basis of this study. Pathological results, therefore, were subgrouped under "nondiagnostic/unsatisfactory" (Category I), "benign" (Category II), and "atypia/neoplasia/malignancy" (Category III-VI).

Results:  Both FNAB groups were not statistically different or only slightly different regarding size ( = 0.196), echogenicity ( = 0.014), and the presence of echogenic foci ( = 0.11), therefore considered to have equal USG properties. In MPCS method, the nondiagnostic/unsatisfactory rate (i.e., Category I) was 24%. Other cytological results were as follows: Category II (67.1%), Category III-VI (8.8%). In SPLBC method, the nondiagnostic/unsatisfactory rate (i.e., Category I) was 14.5%. Other cytological results were as follows: Category II (77.6%), Category III-VI (7.8%). A significant difference was found between two sampling methods regarding pathological results (Independent samples t-test,  < 0.0001). The demographic and USG factors, considered in this study, did not offer a successful prediction of nondiagnostic/unsatisfactory outcomes.

Conclusion:  SPLBC has significantly lower (14.5% vs 24%) nondiagnostic rate than MPCS, and higher 77.6% vs 67.1%) Category II rate than MPCS. This may point to the possibility that MPCS method undercategorizes many benign (i.e., Category II) nodules under nondiagnostic/unsatisfactory category. The success of the former is due to the elimination of confounding material during the process. Single pass, also, increases patient comfort and compliance, and has additional advantages for the interventionalist, as it obviates the need to smear aspirates. This dramatically decreases the actual duration of the biopsy procedure and is free of interventionalist expertise for smearing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7034764PMC
http://dx.doi.org/10.7759/cureus.6740DOI Listing

Publication Analysis

Top Keywords

liquid-based cytology
12
category
11
methods fine
8
fine needle
8
needle aspiration
8
aspiration biopsy
8
thyroid nodules
8
usg factors
8
conventional smear
8
single pass
8

Similar Publications

: Implementing self-sampling (SS) in cervical cancer screening requires comparable results to clinician-collected samples (CCS). Agreement measures are essential for evaluating HPV test performance. Previous studies on non-paired samples have reported higher viral cycle threshold (Ct) values in SS compared to CCS, affecting sensitivity for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+).

View Article and Find Full Text PDF

Study on the Transformation Process of Thyroid Fine-Needle Aspiration Liquid-Based Cytology to Whole-Slide Image.

Cytopathology

January 2025

National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China.

Objective: Analyse and summarise the reasons for failure in the digital acquisition of thyroid liquid-based cytology (LBC) slides and the technical challenges, and explore methods to obtain reliable and reproducible whole digital slide images for clinical thyroid cytology.

Method: Use the glass slide scanning imaging system to acquire whole-slide image (WSI) of thyroid LBC in sdpc format through different. Statistical analysis was conducted on the different acquisition methods, the quality of the glass slides, clinical and pathological characteristics of the case, TBSRTC grading and the quality of WSI.

View Article and Find Full Text PDF

Primary bronchial leiomyosarcoma: a diagnostic challenge.

BMC Pulm Med

January 2025

Department of Pathology, Affiliated Hospital of Zunyi Medical University, Zunyi City, Guizhou Province, P.R. China.

Background: Pulmonary bronchial leiomyosarcoma is an extremely rare malignant tumour of the lung originating from the mesenchymal tissue. The retroperitoneal region is the most common site of leiomyosarcoma. It exhibits a high degree of malignancy and a poor prognosis, thereby highlighting the significance of early diagnosis of this disease.

View Article and Find Full Text PDF

MicroRNA-Based Liquid Biopsy for Cervical Cancer Diagnostics and Treatment Monitoring.

Int J Mol Sci

December 2024

National Medical Research Center for Obstetrics, Gynecology and Perinatology Named After Academician V.I. Kulakov, Ministry of Healthcare of the Russian Federation, Moscow 117997, Russia.

Despite prevention strategies, cervical cancer remains a significant public health issue. Human papillomavirus plays a critical role in its development, and early detection is vital to improve patient outcomes. The incidence of cervical cancer is projected to rise, necessitating better diagnostic tools.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!