Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To investigate if the performance of Pediatric Index of Mortality 3 is improved by including imputed values for the PaO2/FIO2 ratio where measurements of PaO2 or FIO2 are missing.
Design: A prospective observational study.
Setting: A bi-national pediatric intensive care registry.
Patients: The records of 37,983 admissions of children less than 16 years old admitted to 19 ICUs.
Interventions: None.
Measurements And Main Results: Seven published equations describing an association between PaO2/FIO2 and oxygen saturation measured by pulse oximetry (SpO2)/FIO2 were used to derive an alternative variable d100 × FIO2/PaO2 for the Pediatric Index of Mortality 3 variable 100 × FIO2/PaO2. Six equations exclude SpO2/FIO2 values if SpO2 is greater than 96-98%. 100 × FIO2/PaO2 was missing in 72% of patient records primarily due to missing PaO2, d100 × FIO2/PaO2 was missing in 71% of patient records if values of SpO2greater than 97% were excluded or in 17% of patient records if all measurements of SpO2 were included. Univariable analysis supported the inclusion of SpO2 values greater than 97%. Compared to the standard Pediatric Index of Mortality 3 model, two alternative models imputing 100 × FIO2/PaO2 from d100 × FIO2/PaO2 only if 100 × FIO2/PaO2 was missing, or using d100 × FIO2/PaO2 values exclusively, resulted in a small but statistically significant improvements in discrimination of Pediatric Index of Mortality 3 (area under the receiver operator curve 0.9068 [0. 8965-0. 9171]; 0.9083 [0.8981-0.9184]; 0.9087 [0.8987-0.9188], respectively).
Conclusions: Imputation of the PaO2/FIO2 ratio in cases where arterial sampling was not performed resulted in a large reduction in the rate of missing data if all values of SpO2 were included. The imputation technique improved the discrimination of Pediatric Index of Mortality 3; however, the magnitude of the increment in overall model performance was small. A possible benefit of the approach is reducing the potential for bias resulting from variation in practice for invasive monitoring of oxygenation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/PCC.0000000000002233 | DOI Listing |