Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Matrix effects have been shown to be very pronounced and highly variable in the analysis of mobile chemicals, which may severely exacerbate accurate quantification. These matrix effects, however, are still scarcely studied in combination with hydrophilic interaction liquid chromatography (HILIC) and for very polar chemicals. In this study, the matrix effects of 26 polar model analytes were investigated in enriched drinking water, wastewater treatment plant effluent and solutions of inorganic salts, utilizing post-column infusion of the analytes into a HILIC-electrospray ionisation (ESI)-high-resolution mass spectrometry system. These experiments revealed the occurrence of structure-specific and unspecific matrix effects. The unspecific matrix effects were mainly observed in positive ESI polarity and predominantly coincided with a high ion count, resulting in ion suppression of all analytes. Thus, the excess charge is hypothesized to be the limiting factor in ion formation. Structure-specific matrix effects were more pronounced in negative ESI polarity and even structurally similar compounds were observed to react entirely differently: perfluoroalkyl carboxylic acids were suppressed, while perfluoroalkane sulfonic acids were simultaneously enhanced. These matrix effects were traced back to inorganic anions and cations, which eluted over a significant fraction of the chromatographic run time with this setup. Hence, it was concluded that inorganic ions are a main cause for matrix effects in the analysis of mobile chemicals utilizing HILIC. Graphical abstract.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00216-020-02548-1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!