The growing field of urinary proteomics shows promise to expand the number of biomarkers for the diagnosis and prognosis of a number of human diseases. With the rapid developments in mass spectrometry methods for proteome quantification, there exists an opportunity for improved sample processing and separation workflows to make important contributions to urine proteomic analyses. Here we evaluate the performance of four sample preparation methods: MStern, PreOmics in-StageTip (iST), suspension-trapping (S-Trap), and conventional urea In-Solution trypsin hydrolysis for nondepleted urine samples. Data-dependent acquisition (DDA) mode on a QExactive HF mass spectrometer was used for single-shot label-free data acquisition. Our results demonstrate a high degree of reproducibility within each workflow. PreOmics iST yields the best digestion efficiency, whereas the S-Trap workflow gives the greatest number of peptide and protein identifications. Using the S-Trap method and starting with ∼0.5 mL, we identify ∼1500 protein groups and ∼17 700 peptides from DDA analysis with a single injection on the mass spectrometer.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.jproteome.9b00772 | DOI Listing |
Eur J Orthop Surg Traumatol
January 2025
Department of Orthopaedic Surgery, University of California San Diego, 200 West Arbor Drive MC 8894, San Diego, CA, 92103, USA.
Purpose: While treatment modalities for Maisonneuve fractures involving the proximal third of the fibula are established, no studies to date have reported outcomes associated with syndesmotic-only fixation of middle third fibular shaft fractures. The purpose of this study was to evaluate outcomes associated with syndesmotic-only fixation in the treatment of Maisonneuve fractures involving the middle third of the fibula.
Methods: A retrospective review was conducted on 257 cases of syndesmotic ankle instability with associated fibular fractures at a level 1 trauma center between 2013 and 2023.
Mikrochim Acta
January 2025
Department of Chemistry, Sardar Vallabhbhai National Institute of Technology, Surat, Gujarat, 395 007, India.
A fluorescence "turn-off-on" nanoprobe is designed by using europium-doped strontium molybdate perovskite quantum dots (Eu:SMO PQDs) for the sequential detection of hypoxanthine (Hx) and Fe. The Eu:SMO PQDs were prepared by the sol-gel method using Sr(NO), (NH)MoO.4HO, and Eu(OCOCH) as precursors.
View Article and Find Full Text PDFJ Microsc
January 2025
Department of Mechanical, Materials and Aerospace Engineering, University of Liverpool, Liverpool, UK.
Electron backscatter diffraction (EBSD) has developed over the last few decades into a valuable crystallographic characterisation method for a wide range of sample types. Despite these advances, issues such as the complexity of sample preparation, relatively slow acquisition, and damage in beam-sensitive samples, still limit the quantity and quality of interpretable data that can be obtained. To mitigate these issues, here we propose a method based on the subsampling of probe positions and subsequent reconstruction of an incomplete data set.
View Article and Find Full Text PDFSmall
January 2025
Nanotechnology and Bio-Engineering Research Group, Atlantic Technological University, ATU Sligo, Ash Lane, Sligo, F91 YW50, Ireland.
The rising demand for efficient energy storage in flexible electronics is driving the search for materials that are well-suited for the fabrication of these devices. Layered Double Hydroxides (LDHs) stand out as a remarkable material with a layered structure that embodies exceptional electrochemical properties. In this study, both double-shelled and single-shelled NiFe-Layered Double Hydroxide (LDH) particles are prepared using spindle-shaped MIL-101(Fe) as the template.
View Article and Find Full Text PDFJ Clin Med
December 2024
Dentistry and Maxillo-Facial Surgery Unit, Department of Surgery, Dentistry, Paediatrics and Gynaecology (DIPSCOMI), University of Verona, Piazzale L.A. Scuro 10, 37134 Verona, Italy.
The aim of this retrospective study was to compare the histomorphometry of post-extractive sites previously grafted with deproteinized bovine bone, with or without the association of a calcium sulphate preparation. The retrospective evaluation comprehended patients previously selected and treated for the extraction of one or more mono-radicular teeth, followed by an implant-prosthetic rehabilitation. Post-extractive sites had been randomly assigned to test or control group, respectively, if deproteinized bovine bone was used in association with a calcium sulphate preparation or alone.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!