Background: Motor neuron disease includes a spectrum of neurodegenerative diseases with progressive courses and unfavorable prognoses. Here, we described a patient with a lumbar disc herniation (LDH) and isolated bulbar palsy (IBP), who successfully underwent a transforaminal full-endoscopic discectomy (TFED) without incurring the added risks of general anesthesia.

Case Description: A 58-year-old male with IBP had an LDH at the L4-L5 level. Avoiding general anesthesia, a TFED was successfully performed under local anesthesia with mild sedation. There were no perioperative complications, and the patient was discharged on the 1 postoperative day. The patient experienced complete relief of radicular symptomatology 1 year postoperatively.

Conclusion: Here, we present a rare instance of a patient with IBP who successfully underwent a TFED for an LDH performed under local anesthesia utilizing mild sedation, avoiding the risks of general anesthesia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7049887PMC
http://dx.doi.org/10.25259/SNI_581_2020DOI Listing

Publication Analysis

Top Keywords

ibp underwent
8
risks general
8
general anesthesia
8
performed local
8
local anesthesia
8
mild sedation
8
role full-endoscopic
4
full-endoscopic lumbar
4
lumbar discectomy
4
discectomy patients
4

Similar Publications

Purpose: To evaluate the incidence and to describe the characteristics of the intrableb pigmentation (IBP) following XEN63 implantation.

Methods: Retrospective case series of three eyes presenting a pigment dispersion in the filtering bleb after a XEN63 implantation for uncontrolled IOP. Demographic, clinical and imaging data were obtained from medical records.

View Article and Find Full Text PDF

Purpose: Historically, infraclavicular brachial plexus injuries (IBPIs) were considered neuropraxic injuries that would improve with nonsurgical intervention. However, more recent studies suggest that these injuries may benefit from surgical intervention. The aims of this retrospective study were to (1) describe injury patterns and associated injuries of isolated, traumatic IBPIs, (2) evaluate the concordance of preoperative ultrasound and magnetic resonance neurography with surgical findings of patients who underwent surgical intervention for IBPIs, and (3) describe outcomes of surgical intervention for these injuries.

View Article and Find Full Text PDF

Background: In breast reconstruction using the abdominal perforator flap, if the flap capacity is too large, secondary revision procedures can be performed to reduce flap volume and reconstruct the inframammary fold (IMF). We examined the various revision methods and cosmetic results.

Methods: This study included 28 patients who underwent secondary revision among 216 patients who had breast reconstruction using the abdominal perforator flap between April 2012 and March 2019.

View Article and Find Full Text PDF

Background And Aim: The aim of this study was to evaluate the role of intrabiliary pressure (IBP) in the pathophysiology of extrahepatic biliary obstruction (EHBO) during percutaneous transhepatic biliary drainage (PTBD).

Materials And Methods: Adult patients with EHBO who underwent PTBD were prospectively enrolled. IBP was recorded during primary PTBD.

View Article and Find Full Text PDF

Effect of thermal cycling on the flexure strength of CAD-CAM denture base materials: An in vitro study.

J Prosthet Dent

September 2024

Professor, Department of Restorative Sciences, University of Alabama at Birmingham, School of Dentistry, Birmingham, Ala. Electronic address:

Statement Of Problem: The impact of thermal cycling on the flexure strength of contemporary denture base materials remains inadequately understood despite its crucial role in determining the long-term performance of complete dentures.

Purpose: The purpose of this in vitro study was to evaluate the flexural strength of different CAD-CAM denture base materials and the effects of thermal cycling.

Material And Methods: A total of 120 rectangular specimens were fabricated from 6 denture base materials according to the International Organization for Standardization (ISO) 20795-1:2013 standard: a heat-compressed PMMA ([Lucitone 199 [C-L199]), 2 brands of milled material (Ivotion Base [M-IB] and Lucitone Digital Fit [M-LDF]), and 3 types of 3- dimensionally (3D) printed material (Lucitone Digital Print [P-LDP], Flexcera Base [P-FB], and FotoDent Dentures [P-FD]).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?