Objective: To describe cochlear implant performance outcomes in adult patients in whom no intraoperative electrically evoked compound action potential (ECAP) responses were able to be obtained despite intracochlear electrode placement.
Study Design: Retrospective case review.
Setting: Academic tertiary center.
Subjects And Methods: Patients 18 years of age and older undergoing cochlear implantation between May 2010 and September 2018 with absent ECAP measurements intraoperatively with intracochlear electrode positioning were identified. Patient performance on sentence recognition testing using the Hearing in Noise Test (HINT) and AzBio at 6 to 12 months postoperatively was compared to preimplantation scores. Additional collected data included patient demographics, etiology of hearing loss, and preoperative pure-tone average (PTA) and word recognition scores (WRSs).
Results: Intraoperative ECAP measurements were unable to be obtained in 15 cochlear implants performed on 14 patients out of 383 cochlear implant cases. Of the patients with absent ECAP measures, the mean ± SD age was 61.7 ± 15.7 years. Causes of hearing loss included congenital hearing loss, meningitis, autoimmune inner ear disease, otosclerosis, presbycusis, and Ménière's disease. The average preoperative PTA was 103.5 ± 17.0 dB. Twelve implanted ears had a WRS of 0% and 9 had a HINT score of 0% prior to surgery. The mean HINT score at 6 to 12 months postimplantation was 57.8% ± 37.8% and had improved by 42.6% ± 35.6% compared to the mean preimplantation HINT score (95% confidence interval, 22.0%-63.1%, = .001, paired Student test).
Conclusion: There is a wide range of cochlear implant performance in patients with absent intraoperative ECAP measures ranging from sound awareness to HINT scores of 100%.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0194599820907572 | DOI Listing |
PLoS One
January 2025
Department of Clinical Neurosciences, University of Cambridge, Cambridge, United Kingdom.
Background: Cochlear implants (CI) with off-the-ear (OTE) and behind-the-ear (BTE) speech processors differ in user experience and audiological performance, impacting speech perception, comfort, and satisfaction.
Objectives: This systematic review explores audiological outcomes (speech perception in quiet and noise) and non-audiological factors (device handling, comfort, cosmetics, overall satisfaction) of OTE and BTE speech processors in CI recipients.
Methods: We conducted a systematic review following PRISMA-S guidelines, examining Medline, Embase, Cochrane Library, Scopus, and ProQuest Dissertations and Theses.
Int J Audiol
January 2025
Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, USA.
Objectives: An improvement in speech perception is a major well-documented benefit of cochlear implantation (CI), which is commonly discussed with CI candidates to set expectations. However, a large variability exists in speech perception outcomes. We evaluated the accuracy of clinical predictions of post-CI speech perception scores.
View Article and Find Full Text PDFIntroduction: Neurotrophic factors are widely known for their protective effect on spiral ganglion neurons (SGN) and the protection of these neurons is of great importance to optimize Cochlear Implants, which directly stimulate SGN in deaf patients. Previous studies have identified Cometin - also known as Meteroin-like - to be neuroprotective and beneficial for metabolic disorders. The aim of our study was to investigate the effects of different concentrations of recombinant human Cometin (hCometin) on SGN in regard to neuroprotection and neurite outgrowth and to evaluate its neurite guidance potential using a neurite outgrowth chamber.
View Article and Find Full Text PDFInt J Audiol
January 2025
Department of Otorhinolaryngology, Radboud University Medical Center, Nijmegen, The Netherlands.
Objective: To assess the impact of cochlear implantation (CI) and speech perception outcomes on the quality of life (QoL) of adult CI users and their communication partners (CP) one-year post-implantation.
Design: This research is part of a prospective multicenter study in The Netherlands, called SMILE (Societal Merit of Intervention for hearing Loss Evaluation).
Study Sample: Eighty adult CI users completed speech perception testing and the Nijmegen Cochear Implant Questionnaire (NCIQ).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!