A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Efficacy and safety of water-exchange enteroscopy compared to carbon dioxide insufflation during enteroscopy. | LitMetric

Introduction: carbon dioxide (CO2) insufflation during enteroscopy reduces procedure time and subsequent symptoms and increases the insertion depth compared with room air. In colonoscopy, the water-exchange (WE) technique is associated with less pain compared with CO2 insufflation. The WE technique is not well studied in enteroscopy. The aim of this study was to compare the efficacy and safety of enteroscopy with WE and CO2.

Methods: a prospective, comparative and observational study was performed of double balloon enteroscopies (DBE) that were randomized in two groups. The first group used WE while the second group used CO2 insufflation. The data collected was evaluated via univariate analysis and multiple logistic regression (variables with p ≤ 0.10 according to the univariate analysis).

Results: forty-six DBE were included; 23 in each arm. The median age of cases was 63.5 years and 37% were female. There were no statistical differences between the groups with regard to the access route, findings, therapy and complications. Four patients (20%) in the CO2 group had adverse events (abdominal distension and pain) and one in the WE group (nausea), which was not statistically significant. The median insertion depth was greater in the CO2 group; 260 cm vs 160 cm (p = 0.048). Multiple logistic regression showed a statistically significant difference in the insertion depth using CO2 insufflation (OR 1.009, 1.001-1.017; p = 0.034).

Conclusions: DBE with a CO2 insufflation technique and WE are safe with a greater insertion depth with CO2.

Download full-text PDF

Source
http://dx.doi.org/10.17235/reed.2020.6788/2019DOI Listing

Publication Analysis

Top Keywords

co2 insufflation
20
insertion depth
16
efficacy safety
8
carbon dioxide
8
insufflation enteroscopy
8
co2
8
insufflation technique
8
multiple logistic
8
logistic regression
8
co2 group
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!