We study double ionization (DI) dynamics of vibrating HeH versus its isotopic variant HeT in strong laser fields numerically. Our simulations show that for both cases, these two electrons in DI prefer to release together along the H(T) side. At the same time, however, the single ionization (SI) is preferred when the first electron escapes along the He side. This potential mechanism is attributed to the interplay of the rescattering of the first electron and the Coulomb induced large ionization time lag. On the other hand, the nuclear motion increases the contributions of these two electrons releasing together along the He side. This effect differentiates DI of HeH from HeT.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.384242DOI Listing

Publication Analysis

Top Keywords

double ionization
8
ionization dynamics
8
dynamics vibrating
8
vibrating heh
8
heh versus
8
strong-field double
4
ionization
4
versus het
4
het study
4
study double
4

Similar Publications

The single crystals of lead-free NaBiTiO were grown using the Czochralski method. The energy gaps determined from X-ray photoelectron spectroscopy (XPS) and optical measurements were approximately 2.92 eV.

View Article and Find Full Text PDF

Purpose: To assess the impact of autologous serum (AS) tears at a 50% concentration on the ocular surface of patients with refractory dry eye disease (DED) because of Sjogren syndrome.

Methods: Twenty eyes of ten patients with severe immune-mediated DED were contralaterally randomized to receive either AS tears 50% or artificial tears between June 2021 and May 2023. Changes in tear stability, ocular surface staining, and in the morphology of the corneal sub-basal nerves were evaluated before treatment and at 1, 2, and 3 months after treatment using objective tests for DED and confocal microscopy.

View Article and Find Full Text PDF

Electronic spectra for OThF have been recorded using fluorescence excitation and two-photon resonantly enhanced ionization techniques. Multiple vibronic bands were observed in the 340-460 nm range. Dispersed fluorescence spectra provided ground state vibrational constants and evidence of extensive vibronic state mixing at higher excitation energies.

View Article and Find Full Text PDF

Background: The serum calcification propensity test (or T50 test) might become a standard tool for the assessment of vascular calcification risk and T50 might be a valuable biomarker in clinical trials of treatments intended to slow the progression of vascular calcification. Literature data suggest that non-calcium-containing phosphate binders can influence T50 in chronic dialysed patients. However, it is not clear whether similar interventions are effective in patients at earlier stages of chronic kidney disease (CKD).

View Article and Find Full Text PDF

Structure of the Se Isomers─An Ab Initio Study.

J Phys Chem A

January 2025

Institute of Atomic and Molecular Physics, Jilin University, Changchun 130012, China.

This study investigates the equilibrium geometries of four different Se isomers using the coupled cluster single and double perturbative (CCSD(T)) method, extrapolating to the complete basis sets. The ground-state geometry of the Se isomer with the C structure (2.8715 Å, 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!