Nonlinear interferometers allow spectroscopy in the mid-infrared range by detecting correlated visible light, for which non-cooled detectors with higher specific detectivity and lower dark count rates are available. We present a new approach for the registration of spectral information, which combines a nonlinear interferometer using non-degenerate spontaneous parametric down-conversion (SPDC) with a Fourier-transform spectroscopy concept. In order to increase the spectral coverage, we use broadband non-collinear SPDC in periodically poled LiNbO. Without the need for spectrally selective detection, continuous spectra with a spectral bandwidth of more than 100 cm are achieved. We demonstrate transmission spectra of a polypropylene sample measured with 6 cm resolution in the spectral range between 3.2 µm to 3.9 µm.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.382351DOI Listing

Publication Analysis

Top Keywords

visible light
8
fourier transform
4
transform infrared
4
infrared spectroscopy
4
spectroscopy visible
4
light nonlinear
4
nonlinear interferometers
4
interferometers allow
4
allow spectroscopy
4
spectroscopy mid-infrared
4

Similar Publications

Germline inactivating mutations of the SLC25A1 gene contribute to various human disorders, including Velocardiofacial (VCFS), DiGeorge (DGS) syndromes and combined D/L-2-hydroxyglutaric aciduria (D/L-2HGA), a severe systemic disease characterized by the accumulation of 2-hydroxyglutaric acid (2HG). The mechanisms by which SLC25A1 loss leads to these syndromes remain largely unclear. Here, we describe a mouse model of SLC25A1 deficiency that mimics human VCFS/DGS and D/L-2HGA.

View Article and Find Full Text PDF

During maritime operations, extreme events such as explosions, grounding, and seal failures can cause water ingress into lubricant compartments, forming oil-water emulsions that significantly affect the lubrication performance of ship stern bearings. Existing studies mainly focus on low water content, with limited exploration of the impact of high water content on lubrication performance. To address this gap, viscosity measurements of oil-water mixtures were conducted, and an emulsification viscosity equation applicable to varying water contents was derived.

View Article and Find Full Text PDF

Added safety measures coupled with the development and use of pathogen reduction technologies (PRT) significantly reduces the risk of transfusion-transmitted infections (TTIs) from blood products. Current approved PRTs utilize chemical and/or UV-light based inactivation methods. While the effectiveness of these PRTs in reducing pathogens are well documented, these can cause tolerable yet unintended consequences on the quality and efficacy of the transfusion products.

View Article and Find Full Text PDF

This study proposes a novel, highly sensitive neutron detector design utilizing a unique multi-layered configuration. Each layer consists of a LiF: ZnS(Ag) scintillator coupled with a transparent neutron moderator that also functions as a light guide for the Silicon Photomultiplier (SiPM) light sensor. This design offers a cost-effective and readily available alternative for existing neutron detectors.

View Article and Find Full Text PDF

Studies of in situ plant response and adaptation to complex environmental stresses, are crucial for understanding the mechanisms of formation and functioning of ecosystems of anthropogenically transformed habitats. We study short- and long-term responses of photosynthetic apparatus (PSA) and anti-oxidant capacity to complex abiotic stresses of common plants Calamagrostis epigejos and Solidago gigantea in semi-natural (C) and heavy metal contaminated habitats (LZ). We found significant differences in leaf pigment content between both plant species growing on LZ plots and their respective C populations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!