A Tactile Device Generating Repulsive Forces of Various Human Tissues Fabricated from Magnetic-Responsive Fluid in Porous Polyurethane.

Materials (Basel)

Smart Structure and Systems Laboratory, Department of Mechanical Engineering, Inha University, Incheon 22212, Korea.

Published: February 2020

In this study, a controllable tactile device capable of realizing repulsive forces from soft human tissues was proposed, and its effectiveness was verified through experimental tests. The device was fabricated using both porous polyurethane foam (PPF) and smart magnetorheological fluid (MRF). As a first step, the microstructural behavior of MRF particle chains that depended on the magnetic field was examined via scanning electron microscopy (SEM). The test samples were then fabricated after analyzing the magnetic field distribution, which was crucial for the formation of the particle chains under the squeeze mode operation. In the fabrication of the samples, MRF was immersed into the porous polyurethane foam and encapsulated by adhesive tape to avoid leakage. To verify the effectiveness of the proposed tactile device for appropriate stiffness of soft human tissues such as liver, the repulsive force and relaxation stress were measured and discussed as a function of the magnetic field intensity. In addition, the effectiveness and practical applicability of the proposed tactile device have been validated through the psychophysical test.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7084753PMC
http://dx.doi.org/10.3390/ma13051062DOI Listing

Publication Analysis

Top Keywords

tactile device
16
human tissues
12
porous polyurethane
12
magnetic field
12
repulsive forces
8
soft human
8
polyurethane foam
8
particle chains
8
proposed tactile
8
tactile
4

Similar Publications

Anti-freezing conductive hydrogels with exceptional mechanical properties and stable sensing performance at -30 °C.

Mater Horiz

January 2025

Tianjin Key Laboratory of Composite and Functional Materials, School of Materials Science and Engineering, Tianjin University, Tianjin, 300350, P. R. China.

Conductive hydrogels with stable sensing performance are highly required in soft electronic devices. However, these hydrogels tend to solidify and experience structural damage at sub-zero temperatures, leading to material breakdown and device malfunction. The main challenge lies in effectively designing the micro/nano-structure to enhance mechanical properties and stable strain sensing while preventing freezing in hydrogels.

View Article and Find Full Text PDF

Role of Robotics in Image-Guided Trans-Arterial Interventions.

Tech Vasc Interv Radiol

December 2024

Division of Vascular and Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, Washington, DC; Georgetown University School of Medicine, Washington, DC; Lombardi Comprehensive Cancer Center, Washington, DC. Electronic address:

The integration of robotic systems in image-guided trans-arterial interventions has revolutionized the field of Interventional Radiology (IR), offering enhanced precision, safety, and efficiency. These advancements are particularly impactful for acute conditions such as stroke, pulmonary embolism, and STEMI, where timely intervention is critical. Robotic platforms like the CorPath GRX and Magellan allow for remote navigation and catheter-based interventions, making it possible to extend specialized services to remote and underserved areas.

View Article and Find Full Text PDF

Navigating the complexity of touch.

Science

January 2025

Laboratory for Bionic Integration, Department of Biomedical Engineering, Lerner Research Institute and Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, OH, USA.

Precise cortical microstimulation improves tactile experience in brain-machine interfaces.

View Article and Find Full Text PDF

Flexible tactile sensors have received significant attention for use in wearable applications such as robotics, human-machine interfaces, and health monitoring. However, conventional tactile sensors face challenges in accurately measuring pressure because vertical deformation is induced by Poisson's ratio in situations where lateral strain is applied. This study shows a strain-insensitive flexible tactile sensor array without the crosstalk effect using a highly stretchable mesh.

View Article and Find Full Text PDF

A recurring challenge in extracting energy from ambient motion is that devices must maintain high harvesting efficiency and a positive user experience when the interface is undergoing dynamic compression. We show that small amphiphiles can be used to tune friction, haptics, and triboelectric properties by assembling into specific conformations on the surfaces of materials. Molecules that form multiple slip planes under pressure, especially through π-π stacking, produce 80 to 90% lower friction than those that form disordered mesostructures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?