Background And Aims: We performed a meta-analysis of all published studies to determine the diagnostic accuracy of artificial intelligence (AI) on histology prediction and detection of colorectal polyps.

Method: We searched Embase, PubMed, Medline, Web of Science, and Cochrane library databases to identify studies using AI for colorectal polyp histology prediction and detection. The quality of included studies was measured by the Quality Assessment of Diagnostic Accuracy Studies tool. We used a bivariate meta-analysis following a random-effects model to summarize the data and plotted hierarchical summary receiver operating characteristic curves. The area under the hierarchical summary receiver operating characteristic curve (AUC) served as an indicator of the diagnostic accuracy and during head-to-head comparisons.

Results: A total of 7680 images of colorectal polyps from 18 studies were included in the analysis of histology prediction. The accuracy of the AI (AUC) was .96 (95% confidence interval [CI], .95-.98), with a corresponding pooled sensitivity of 92.3% (95% CI, 88.8%-94.9%) and specificity of 89.8% (95% CI, 85.3%-93.0%). The AUC of AI using narrow-band imaging (NBI) was significantly higher than the AUC using non-NBI (.98 vs .84, P < .01). The performance of AI was superior to nonexpert endoscopists (.97 vs .90, P < .01). For characterization of diminutive polyps using a deep learning model with nonmagnifying NBI, the pooled negative predictive value was 95.1% (95% CI, 87.7%-98.1%). For polyp detection, the pooled AUC was .90 (95% CI, .67-1.00) with a sensitivity of 95.0% (95% CI, 91.0%-97.0%) and a specificity of 88.0% (95% CI, 58.0%-99.0%).

Conclusions: AI was accurate in histology prediction and detection of colorectal polyps, including diminutive polyps. The performance of AI was better under NBI and was superior to nonexpert endoscopists. Despite the difference in AI models and study designs, AI performances are rather consistent, which could serve as a reference for future AI studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gie.2020.02.033DOI Listing

Publication Analysis

Top Keywords

histology prediction
20
colorectal polyps
12
diagnostic accuracy
12
prediction detection
12
accuracy artificial
8
artificial intelligence
8
intelligence histology
8
detection colorectal
8
hierarchical summary
8
summary receiver
8

Similar Publications

Background And Aims: The performance of non-invasive liver tests (NITs) is known to vary across settings and subgroups. We systematically evaluated whether the performance of three NITs in detecting advanced fibrosis in patients with metabolic dysfunction-associated steatotic liver disease (MASLD) varies with age, sex, body mass index (BMI), type 2 diabetes mellitus (T2DM) status or liver enzymes.

Methods: Data from 586 adult LITMUS Metacohort participants with histologically characterised MASLD were included.

View Article and Find Full Text PDF

Advances in liver organoids: replicating hepatic complexity for toxicity assessment and disease modeling.

Stem Cell Res Ther

January 2025

Organoid Innovation Center, Suzhou Institute of Nanotech and Nano-bionics, Chinese Academy of Sciences, 398 Ruoshui Rd, Suzhou, Jiangsu, 215123, China.

The lack of in vivo accurate human liver models hinders the investigation of liver-related diseases, injuries, and drug-related toxicity, posing challenges for both basic research and clinical applications. Traditional cellular and animal models, while widely used, have significant limitations in replicating the liver's complex responses to various stressors. Liver organoids derived from human pluripotent stem cells, adult stem cells primary cells, or tissues can mimic diverse liver cell types, major physiological functions, and architectural features.

View Article and Find Full Text PDF

Background: Bone-invasive Pituitary Neuroendocrine Tumors (BI PitNETs) epitomize an aggressive subtype of pituitary tumors characterized by bone invasion, culminating in extensive skull base bone destruction and fragmentation. This infiltration poses a significant surgical risk due to potential damage to vital nerves and arteries. However, the mechanisms underlying bone invasion caused by PitNETs remain elusive, and effective interventions for PitNET-induced bone invasion are lacking in clinical practice.

View Article and Find Full Text PDF

Background: Histone H2B is highly expressed in many types of cancers and is involved in cancer development. H2B clustered histone 9 (H2BC9), a member of the H2B family, plays critical roles in gene expression regulation, chromosome structure, DNA repair stability, and cell cycle regulation. However, the diagnostic and prognostic value of H2BC9 in head and neck squamous cell carcinoma (HNSCC) remains unclear.

View Article and Find Full Text PDF

External validation of a multivariable prediction model for positive resection margins in breast-conserving surgery.

BMC Res Notes

January 2025

Department of Surgery, Department of Clinical Sciences, Division of Surgery, Skåne University Hospital, Lund University, Lund, Sweden.

Objectives: Positive resection margins after breast-conserving surgery (BCS) most often demands a repeat surgery. To preoperatively identify patients at risk of positive margins, a multivariable model has been developed that predicts positive margins after BCS with a high accuracy. This study aimed to externally validate this prediction model to explore its generalizability and assess if additional preoperatively available variables can further improve its predictive accuracy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!