Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Antidepressant drugs are one of the most widely used medicines for treating major depressive disorders for long time periods. Oral fluid (OF) testing offers an easy and non-invasive sample collection. Detection of antidepressants in OF is important in clinical and forensic settings, such as therapeutic drug monitoring and roadside testing for driving under influence. We developed and validated a comprehensive liquid chromatography-tandem mass spectrometry method for 18 antidepressants (amitriptyline, bupropion, citalopram, clomipramine, cyclobenzaprine, desipramine, desvenlafaxine, doxepin, duloxetine, fluoxetine, imipramine, mirtazapine, nortriptyline, paroxetine, sertraline, trazodone, trimipramine, venlafaxine) in oral fluid collected by Quantisal® oral collection devices. One-half milliliter of Quantisal® OF (125 μL of neat OF) was submitted to solid-phase extraction. The chromatographic separation was performed employing a biphenyl column in gradient mode with a total run time of 5 min. The MS detection was achieved by multiple-reaction monitoring with two transitions per compound. The range for linearity of all analytes was from 10 to 1,000 ng/mL, with a limit of detection of 10 ng/mL. Intra and inter-day accuracy and precision (n = 15) were all within acceptable limits, ±20% error and ±15% relative standard deviation. Analyte recovery at 400 ng/mL concentration (n = 15) ranged from 91 to 129%. Matrix effect ranged from 73.7 to 157%. The internal proficiency test detected all antidepressants with accuracy ranging from 83.1 to 112.1%. The authentic patient sample showed a percentage difference compared to the previously calculated concentration of 86.3-111%. This method provides for the rapid detection of 18 antidepressants and metabolites in OF, which is readily applicable to a routine laboratory.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/jat/bkz117 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!