A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Developing and Validating a Fast and Accurate Method to Quantify 18 Antidepressants in Oral Fluid Samples Using SPE and LC-MS-MS. | LitMetric

Developing and Validating a Fast and Accurate Method to Quantify 18 Antidepressants in Oral Fluid Samples Using SPE and LC-MS-MS.

J Anal Toxicol

Research and Development Laboratory, Cordant Health Solutions, 789 Park Ave, Huntington, NY 11743, USA.

Published: July 2020

Antidepressant drugs are one of the most widely used medicines for treating major depressive disorders for long time periods. Oral fluid (OF) testing offers an easy and non-invasive sample collection. Detection of antidepressants in OF is important in clinical and forensic settings, such as therapeutic drug monitoring and roadside testing for driving under influence. We developed and validated a comprehensive liquid chromatography-tandem mass spectrometry method for 18 antidepressants (amitriptyline, bupropion, citalopram, clomipramine, cyclobenzaprine, desipramine, desvenlafaxine, doxepin, duloxetine, fluoxetine, imipramine, mirtazapine, nortriptyline, paroxetine, sertraline, trazodone, trimipramine, venlafaxine) in oral fluid collected by Quantisal® oral collection devices. One-half milliliter of Quantisal® OF (125 μL of neat OF) was submitted to solid-phase extraction. The chromatographic separation was performed employing a biphenyl column in gradient mode with a total run time of 5 min. The MS detection was achieved by multiple-reaction monitoring with two transitions per compound. The range for linearity of all analytes was from 10 to 1,000 ng/mL, with a limit of detection of 10 ng/mL. Intra and inter-day accuracy and precision (n = 15) were all within acceptable limits, ±20% error and ±15% relative standard deviation. Analyte recovery at 400 ng/mL concentration (n = 15) ranged from 91 to 129%. Matrix effect ranged from 73.7 to 157%. The internal proficiency test detected all antidepressants with accuracy ranging from 83.1 to 112.1%. The authentic patient sample showed a percentage difference compared to the previously calculated concentration of 86.3-111%. This method provides for the rapid detection of 18 antidepressants and metabolites in OF, which is readily applicable to a routine laboratory.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jat/bkz117DOI Listing

Publication Analysis

Top Keywords

oral fluid
12
detection antidepressants
8
antidepressants
5
developing validating
4
validating fast
4
fast accurate
4
accurate method
4
method quantify
4
quantify antidepressants
4
oral
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!