Assessment of wastewater pollution by gas chromatography and high resolution Orbitrap mass spectrometry.

J Chromatogr A

Analytical Chemistry of Contaminants Research Group, Department of Chemistry and Physics, Andalusian Center for the Assessment and Monitoring of Global Change (CAESCG), University of Almeria, Agrifood Campus of International Excellence, ceiA3, E-04120 Almeria, Spain. Electronic address:

Published: May 2020

AI Article Synopsis

  • * The method showed excellent accuracy and sensitivity, successfully identifying compounds like naphthalene, acenapthene, and phenanthrene in various wastewater samples.
  • * Additionally, the research used an extensive database to identify 51 other pollutants, many of which are commonly found in household products, emphasizing the prevalence of linear alkyl benzenes in the samples.

Article Abstract

As a novelty, the combination of headspace solid phase microextraction and gas chromatography coupled to an Orbitrap mass analyzer in full scan mode (HS-SPME-GC-Orbitrap-MS) was evaluated for the monitoring of organic pollutants in wastewaters. The developed methodology showed good linearity (R > 0.999), sensitivity as well as suitable relative recoveries (89-115%) and precision values (RSD = 1-16%) for 15 polycyclic aromatic hydrocarbons (PAHs) selected as target compounds. Naphthalene, acenapthene and phenanthrene were found in the analyzed samples (influent and effluent wastewaters). Naphthalene was present in 62% of them, ranging from 1.33 to 24.32 ng L. Acenapthene was observed in 1 single sample (4.17 ng L) while phenanthrene was found in 7 samples (1.51-8.67 ng L). In addition, in order to identify other pollutants in the samples, retrospective analyses were addressed through target and non-target screenings. An in-house database containing close to 1,000 pollutants including, among others, polychlorinated biphenyls (PCBs), brominated diphenyl ethers (BDEs) and pesticides, was applied in the post-target analysis. For the non-target screening, after a deconvolution process, high resolution filtering (HRF) and Kovats retention index (KI) were used for tentative analyte identification. Thus, 51 additional pollutants were tentatively identified in the wastewaters, most of them used as flavoring agents and household product ingredients, highlighting the presence of linear alkyl benzenes (LABs).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2020.460964DOI Listing

Publication Analysis

Top Keywords

gas chromatography
8
high resolution
8
orbitrap mass
8
assessment wastewater
4
wastewater pollution
4
pollution gas
4
chromatography high
4
resolution orbitrap
4
mass spectrometry
4
spectrometry novelty
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!