The energy dependence of quantum complex-forming reaction probabilities is well known to involve sharp fluctuations, but little seems to be known about their amplitudes. We develop here, for triatomic reactions, an analytical approach of their statistical distribution. This approach shows that the fluctuation amplitudes depend essentially on the number of available quantum states in the reagent and product channels. Moreover, the more numerous the product states, the more efficiently the fluctuations of their populations compensate each other when they add up to give the reaction probability. The predictions of our approach appear to be in good quantitative agreement with quantum scattering calculations for the prototypical reaction H + H.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.5139207 | DOI Listing |
Anesthesiology
January 2025
Anesthesia and critical care department, Amiens Hospital University, F-80054 Amiens, France.
Background: Cardiac surgery can lead to dysregulation with a pro-inflammatory state, resulting in adverse outcomes. Hemadsorption using the AN69 membrane (Oxiris membrane) has the properties to chelate inflammatory cytokines. We hypothesized that in patients at high risk of inflammation, the use of the Oxiris membrane could decrease inflammation, preserve endothelial function, and improve postoperative outcomes.
View Article and Find Full Text PDFBraz Oral Res
January 2025
Pontifícia Universidade Católica do Rio Grande do Sul - PUC-RS, School of Health and Life Sciences, Department of Pediatric Dentistry, Porto Alegre, RS, Brazil.
The emergence of toothpastes containing different abrasive and whitening substances has been a constant concern among dental professionals. The aim of the present study was to perform an in vitro assessment of the surface topography of nanoparticle composite resins subjected to simulated brushing with dentifrices. Test samples were prepared with Filtek Universal (3M ESPE), Filtek Bulkfill (3M ESPE) and Z350 (3M ESPE), with 24 samples per resin.
View Article and Find Full Text PDFBraz Oral Res
January 2025
Universidade Federal dos Vales do Jequitinhonha e Mucuri UFVJM, School of Biological and Health Sciences, Department of Dentistry, Diamantina, MG, Brazil.
Although it is recognized that periodontal disease negatively impacts quality of life, there is no validated instrument to assess this impact in Brazil. This study aimed to translate, cross-culturally adapt, and validate the OHIP 14 PD (Oral Health Impact Profile Applied to Periodontal Diseases) for application among Brazilian patients. The original instrument was translated and validated into Brazilian Portuguese in a cross-sectional study with 110 participants recruited from a Dental School clinic.
View Article and Find Full Text PDFEnviron Monit Assess
January 2025
School of Metallurgy and Environment, Central South University, Changsha, 410083, Hunan, China.
In this study, an efficient membrane composed of polysulfone and graphene oxide was developed and evaluated for its efficacy in chromium adsorption. Characterization of the synthesized membrane involved comprehensive analyses including scanning electron microscopy (SEM), transmission electron microscopy (TEM), thermogravimetric analysis (TGA) and Fourier-transform infrared spectroscopy (FTIR) to assess its structural properties. Subsequently, the membrane's performance in removing chromium from aqueous solutions was scrutinized, considering key operational parameters.
View Article and Find Full Text PDFClin Oral Investig
January 2025
Department of Conservative Dentistry and Bucofacial Prostheses, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain.
Objectives: This study aimed to assess the vertical misfit at the implant-abutment interface in external and internal connections across various implant brands, comparing original milled titanium abutments with laser-sintered cobalt-chromium (Co-Cr) abutments.
Materials And Methods: A total of 160 implants from four different brands were utilized, with 80 featuring external connections (EC) and 80 internal connections (IC). Original milled titanium abutments (n = 160) and Co-Cr laser-sintered abutments (n = 160) were randomly attached to each connection type, following the manufacturer's recommended torque.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!