Background: Three-dimensional Surface Imaging (3DSI) is a well-established method to objectively monitor morphological changes in the female breast in the field of plastic surgery. In contrast, in radiation oncology we are still missing effective tools, which can objectively and reproducibly assess and document adverse events in breast cancer radiotherapy within the framework of clinical studies. The aim of the present study was to apply structured-light technology as a non-invasive and objective approach for the documentation of cosmetic outcome and early effects of breast radiotherapy as a proof of principle.

Methods: Weekly 3DSI images of patients receiving either conventionally fractionated radiation treatment (CF-RT) or hypofractionated radiation treatment (HF-RT) were acquired during the radiotherapy treatment and clinical follow-up. The portable Artec Eva scanner (Artec 3D Inc., Luxembourg) recorded 3D surface images for the analysis of breast volumes and changes in skin appearance. Statistical analysis compared the impact of the two different fractionation regimens and the differences between the treated and the contralateral healthy breast.

Results: Overall, 38 patients and a total of 214 breast imaging sessions were analysed. Patients receiving CF-RT showed a significantly higher frequency of breast erythema compared to HF-RT (93.3% versus 34.8%, p = 0.003) during all observed imaging sessions. Moreover, we found a statistically significant (p < 0.05) volumetric increase of the treated breast of the entire cohort between baseline (379 ± 196 mL) and follow-up imaging at 3 months (437 ± 224 mL), as well as from week 3 of radiotherapy (391 ± 198 mL) to follow-up imaging. In both subgroups of patients undergoing either CF-RT or HF-RT, there was a statistically significant increase (p < 0.05) in breast volumes between baseline and 3 months follow-up. There were no statistically significant skin or volumetric changes of the untreated healthy breasts.

Conclusions: This is the first study utilizing 3D structured-light technology as a non-invasive and objective approach for the documentation of patients receiving breast radiotherapy. 3DSI offers potential as a non-invasive tool to objectively and precisely monitor the female breast in a radiooncological setting, allowing clinicians to objectively distinguish outcomes of different therapy modalities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7049187PMC
http://dx.doi.org/10.1186/s13014-020-01499-2DOI Listing

Publication Analysis

Top Keywords

three-dimensional surface
8
surface imaging
8
breast cancer
8
patients receiving
8
radiation treatment
8
imaging sessions
8
breast
7
imaging
4
imaging breast
4
cancer tool
4

Similar Publications

Graphene and its derivatives have been widely used as reinforcing nanofillers for high-performance polymer nanocomposites. The effectiveness of the reinforcement largely depends on the properties of the nanofiller-matrix interface, which can be represented by the interfacial shear strength (IFSS). This work systematically investigates IFSS enhancements for polyethylene (PE) nanocomposites reinforced by graphene origami (GOri) through molecular dynamics pull-out simulations.

View Article and Find Full Text PDF

A flexible 3D ordered SERS sensor for rapid and reliable detection of pesticide residues in fruits.

Chem Commun (Camb)

January 2025

Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, China.

We fabricated flexible, three-dimensional (3D) ordered silicon nanowire (SiNW) arrays decorated with high-density silver nanoparticles (AgNPs) for the sensitive and reproducible detection of pesticide residues. These sensors demonstrated a detection limit of 10 M for methyl parathion (MPT) on curved surfaces.

View Article and Find Full Text PDF

Enhanced Protein Immobilization Capacity through Grafting of Poly(sodium methacrylate) onto Magnetic Bead Surface.

Langmuir

January 2025

School of Chemistry and Chemical Engineering, Jiangsu Province Hi-Tech Key Laboratory for Biomedical Research, Southeast University, Nanjing, Jiangsu 211189, P. R. China.

This study aims to improve the signal-to-noise ratio (SNR) of chemiluminescence immunoassay (CLIA) by increasing the amount of protein immobilized on the surface of the magnetic bead (MB). Proteins are macromolecules with three-dimensional structures, and merely increasing the density of functional groups on the two-dimensional surface of the MB cannot significantly enhance protein immobilization. Therefore, we grafted spatially extended functional polymer to not only increase the density of functional groups on the MB surface but also expand their distribution in three-dimensional space, ultimately increasing protein immobilization.

View Article and Find Full Text PDF

Background: Studies have revealed abnormalities of the epiphyseal plate of the distal femur in patients with trochlear dysplasia, but it is unclear whether the epiphyseal plate could be remodeled after surgical correction of patellar dislocation.

Purpose: To investigate whether the morphology of the epiphyseal plate and trochlea could be improved after medial patellar retinaculum plasty in skeletally immature patients and to investigate the correlations between the morphology of the epiphyseal plate and trochlear dysplasia as well as clinical outcomes.

Study Design: Cohort study; Level of evidence, 3.

View Article and Find Full Text PDF

A collicular map for touch-guided tongue control.

Nature

January 2025

Department of Neurobiology and Behavior, Cornell University, Ithaca, NY, USA.

Accurate goal-directed behaviour requires the sense of touch to be integrated with information about body position and ongoing motion. Behaviours such as chewing, swallowing and speech critically depend on precise tactile events on a rapidly moving tongue, but neural circuits for dynamic touch-guided tongue control are unknown. Here, using high-speed videography, we examined three-dimensional lingual kinematics as mice drank from a water spout that unexpectedly changed position during licking, requiring re-aiming in response to subtle contact events on the left, centre or right surface of the tongue.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!