A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Three-Dimensional Printed Targeting Device for Scaphoid Fracture Fixation. | LitMetric

Percutaneous guide wire insertion for scaphoid screw fixation can be challenging and often requires multiple attempts with significant radiation exposure to the surgical team. A 3-dimensional (3D) printed targeting device has the potential to reduce procedure time and intraoperative radiation exposure. Our targeting device protocol included a preprocedure computed tomography (CT) scan of a casted cadaver wrist, followed by 3D printing of a customized targeting guide. In a comparison trial, seven orthopedic surgery residents performed percutaneous scaphoid guide wire insertion on different cadaver specimens by both freehand technique and using our targeting device. Radiation exposure and procedure times were compared. All specimens underwent postprocedure CT to assess Kirschner wire (K-wire) accuracy, determined by central third placement. Pre- and postprocedure CT scans from the targeting device group were co-registered to compare planned and actual K-wire trajectories. Using the freehand technique, mean fluoroscopy time was 120 seconds (standard deviation: ±53 seconds) generating 2.45 milligray of radiation. Average procedure time was 21 minutes with a mean of 6.4 (range: 3-9) insertion attempts. A single insertion attempt was made using the targeting device with an average procedure time of 30 seconds and no fluoroscopy exposure. Four K-wires were placed within the central scaphoid in both groups. Using the targeting device, average linear deviation from the planned trajectory was 2.1 mm, while the maximum linear deviation was 3.75 mm. : When compared to freehand scaphoid guide wire insertion, our targeting device provides similar accuracy while significantly reducing intraoperative radiation exposure and procedure time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8721798PMC
http://dx.doi.org/10.1177/1558944720906502DOI Listing

Publication Analysis

Top Keywords

targeting device
32
radiation exposure
16
procedure time
16
guide wire
12
wire insertion
12
targeting
9
printed targeting
8
device
8
intraoperative radiation
8
scaphoid guide
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!