Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The aim of this study was to determine the incidence of newly detected atrial fibrillation (AF) in patients following dual-chamber pacemaker (PPM) implantation and to define the clinical predictors of new-onset AF in a Chinese cohort.
Methods: A total of 219 patients without documented AF that underwent dual-chamber PPM implantation for sick sinus syndrome (SSS) (n = 88) or atrioventricular block (AVB) (n = 131) were prospectively studied. All patients were invited to follow-up at 1 month, 3 months and 6 months after the pacemaker implantation procedure, and once every 6 months thereafter. An atrial high-rate episode (AHRE) ≥5 min and an atrial rate ≥180 bpm was defined as AF.
Results: During follow-up of 884 ± 180 days, AF was detected in 56 (26%) patients. Using Kaplan-Meier survival curves with Log-rank test, SSS patients with a cumulative percentage of ventricular pacing (Cum % VP) ≥60% had a significantly higher rate of new-onset AF compared to AVB patients (p = 0.026) and SSS patients with Cum % VP <60% (p = 0.018). On multivariate Cox regression analysis, higher Cum % VP independently predicted higher morbidity of newly detected AF (hazard ratio [HR] 1.01; confidence interval [CI] 1.00 ~ 1.02; p = 0.035) among SSS patients. Larger left atrial (LA) dimension was a predictor of newly detected AF (HR 1.06; CI 1.01 ~ 1.14; p = 0.046) in AVB patients.
Conclusion: The incidence of AF following dual-chamber PPM implantation was relatively high in this Chinese cohort. High Cum % VP and larger LA dimension could independently predict new-onset AF after dual-chamber PPM implantation in SSS and AVB patients, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00059-019-04869-z | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!