Background: Aortic valve (AV) repair (AVr) using a central coaptation stitch or bioprosthetic AV replacement (AVR) are most commonly performed at the time of durable left ventricular assist device implant to address AV insufficiency (AI).

Methods: Prospective data collection on 46 patients undergoing left ventricular assist device implant from 2007 through 2018 who received concomitant AVr (n = 40) or AVR (n = 6) was retrospectively analyzed to assess freedom from recurrent aortic insufficiency. Paired Wilcoxon rank-sum test was used to compare echocardiographic findings. Mantel-Cox statistics were used to analyze survival.

Results: For AVr, central coaptation led to a mean decrease in AI severity by 2.1 ± 1.0 grades (P < .001). Three patients (7.5%) had recurrence of at least moderate AI by 3 years. In comparison, all patients in the AVR group had mild or less AI on subsequent follow-up. Success of AVr in downgrading AI severity was associated with a smaller aortic root diameter (P = .011) and sinotubular junction diameter (P = .003). An aortic root diameter greater than 3.5 cm was predictive of less improvement in AI severity compared with 3.5 cm or less (1.83 ± 1.03 versus 2.47 ± 0.80 grades of improvement; P = .038). Duration of cardiopulmonary bypass was 32 minutes longer and duration of aortic cross-clamp was 38 minutes longer for AVR versus AVr cohorts. No difference in 30-day (P = .418) or overall survival (P = .572) between the AVr and AVR groups was seen.

Conclusions: Aortic valve repair for addressing AI has a recurrence rate of 7.5% at 3 years. Success in downgrading AI is more likely with a smaller aortic root. No difference in survival was observed between AVr and AVR.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2020.01.015DOI Listing

Publication Analysis

Top Keywords

avr
13
aortic valve
12
valve repair
12
left ventricular
12
ventricular assist
12
aortic root
12
aortic
8
durable left
8
avr central
8
central coaptation
8

Similar Publications

Pregnancy-related spontaneous coronary artery dissection (P-SCAD) is a life-threatening condition that occurs during or after pregnancy, is rare and can be overlooked. It is one of the most important causes of pregnancy-related acute myocardial infarction. A 25-year-old female patient was admitted with a complaint of chest pain in her 37th week of pregnancy.

View Article and Find Full Text PDF

Aim: To quantitatively analyze the relationship between spherical equivalent refraction (SER) and retinal vascular changes in school-age children with refractive error by applying fundus photography combined with artificial intelligence (AI) technology and explore the structural changes in retinal vasculature in these children.

Methods: We conducted a retrospective case-control study, collecting data on 113 cases involving 226 eyes of schoolchildren aged 6-12 years who attended outpatient clinics in our hospital between October 2021 and May 2022. Based on the refractive spherical equivalent refraction, we categorized the participants into four groups: 66 eyes in the low myopia group, 60 eyes in the intermediate myopia group, 50 eyes in the high myopia group, and 50 eyes in the control group.

View Article and Find Full Text PDF

Background: Surgical aortic valve replacement (SAVR) is the commonly used approach for aortic valve replacement (AVR) in patients with aortic stenosis at low or intermediate surgical risk. However, transcatheter aortic valve replacement (TAVR) has emerged as an alternative to SAVR for AVR. This meta-analysis aims to assess the comparative efficacy and safety of TAVR versus SAVR in low-to-intermediate surgical risk patients by analyzing temporal trends in the outcomes of TAVR and SAVR at various follow-up intervals, providing a more detailed understanding.

View Article and Find Full Text PDF

Purpose: Clinicians monitor scoliosis progression using multiple radiographs during growth. During imaging, arms must be elevated to visualize vertebrae, possibly affecting sagittal alignment. This study aimed to determine the arm position that best represents habitual standing (and possibly allowing hand-based skeletal maturity assessment) to obtain frontal and lateral stereo-radiographs as measured using frontal, sagittal, and transverse angles.

View Article and Find Full Text PDF
Article Synopsis
  • The study focuses on the outcomes of aortic valve replacement (AVR) in young Moroccan patients with severe aortic regurgitation and impaired left ventricle function.
  • A total of 42 out of 110 patients with significant aortic regurgitation and an ejection fraction of ≤35% underwent AVR, showing a low immediate postoperative mortality rate of 4.7%.
  • Long-term follow-up indicated a high survival rate of 86.8% after 15 years, along with significant clinical improvements and increased left ventricle ejection fraction post-surgery.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!