In connection with medicolegal autopsies peripheral blood (e.g. from a femoral vein) is the specimen of choice for toxicological analysis, although alternative specimens are also sometimes submitted, such as bile, cerebrospinal fluid (CSF), vitreous humor (VH), bladder urine, pleural effusions and/or lung fluid. Ethanol concentrations were determined in duplicate in femoral blood and in various alternative biological specimens by headspace gas chromatography. The analysis was carried out on two different fused silica capillary columns furnishing different retention times for ethanol and both n-propanol and t-butanol were used as internal standards. The results were evaluated by linear regression using blood alcohol concentration (BAC) as dependent or outcome variable and the concentrations in an alternative specimen as independent or predictor variable. The Pearson correlation coefficients were all statistically highly significant (P < 0.001); r = 0.94 (bile), r = 0.98 (CSF), r = 0.97 (VH), r = 0.92 (urine), r = 0.94 (lung fluid) and r = 0.96 (pleural cavity effusions). When the regression model was used to predict femoral BAC from the mean concentration in an alternative specimen the mean and 95% prediction intervals were 1.12 ± 0.824 g/L (bile), 1.41 ± 0.546 g/L (CSF), 1.15 ± 0.42 g/L (VH), 1.29 ± 0.780 g/L (urine), 1.25 ± 0.772 g/L (lung fluid) and 0.68 ± 0.564 g/L (pleural cavity effusions). This large uncertainty for a single new observation needs to be considered when alcohol-related deaths are evaluated and interpreted. However, the analysis of alternative specimens is recommended in medical examiner cases to provide supporting evidence with regard to the origin of ethanol, whether this reflects antemortem (AM) ingestion or postmortem (PM) synthesis.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jat/bkaa018DOI Listing

Publication Analysis

Top Keywords

ethanol concentrations
8
femoral blood
8
blood alternative
8
alternative biological
8
biological specimens
8
linear regression
8
high correlation
4
correlation ethanol
4
concentrations postmortem
4
postmortem femoral
4

Similar Publications

The influence of additives and modifiers on the chiral HPLC separation of the nicotine enantiomers using UV/Vis detection is discussed. Selected alcohols as modifiers and selected amines as additives were found to have a significant effect on the resolution and retention times of nicotine enantiomers even to the point of eliminating component elution. Systematic variations in the concentration of ethanol, methanol, and isopropanol, as modifiers, along with variations in the concentration of diethylamine, triethylamine, tributylamine, ethylenediamine, isopropylamine, as additives, revealed that the average resolution (R) of the nicotine enantiomers ranged from 2.

View Article and Find Full Text PDF

Preparation of curcumin submicron particles by supercritical antisolvent method with external adjustable annular gap nozzle.

Sci Rep

January 2025

Key Laboratory of High-efficiency and Clean Mechanical Manufacture (Ministry of Education), National Demonstration Center for Experimental Mechanical Engineering Education (Shandong University), School of Mechanical Engineering, Shandong University, Jinan, 250061, People's Republic of China.

The supercritical antisolvent (SAS) method can effectively improve the bioavailability of poorly water-soluble drugs. However, the current supercritical equipment and processes were not fully developed, making industrialization difficult to achieve. Therefore, an externally adjustable annular gap nozzle and its supporting equipment were designed.

View Article and Find Full Text PDF

Maximizing sorghum proteins printability: Optimizing gel formulation and 3D-printing parameters to develop a novel bioink.

Int J Biol Macromol

January 2025

Department of Food Science, University of Arkansas, Fayetteville, AR 72704, USA; Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, AR 72701, USA. Electronic address:

The objective of this study was to form sorghum protein gels and explore their application in 3D food printing. Sorghum proteins were used to prepare gels with concentrations of 15 %, 20 %, 25 %, 30 %, and 35 % (w/w) in 70 % ethanol. The gels were evaluated for their rheological and textural properties and utilized as bioinks for 3D printing.

View Article and Find Full Text PDF

Study Objective: The osmol gap can help detect and manage those with toxic alcohol exposure, and it is altered by all alcohols including ethanol. The optimal correction for ethanol that would allow accurate detection of an alternative alcohol is unclear.

Methods: We conducted a prospective cohort study to assess baseline variations in osmol gap, and then to assess the validity of 2 commonly used coefficients (correction factors) for ethanol.

View Article and Find Full Text PDF

From solubility to efficiency: Per- and polyfluoroalkyl substances (PFAS) regeneration from anion exchange resins.

Sci Total Environ

January 2025

Department of Civil and Environmental Engineering, Temple University, Philadelphia, PA 19122, USA. Electronic address:

This study investigated the regenerability of anion exchange resins for per- and polyfluoroalkyl substances (PFAS), focusing on the interaction between regenerant composition and resin characteristics. The influence of salt type and concentration on PFAS solubility revealed a general decline in perfluorohexane sulfonate (PFHxS) solubility with increased salt concentrations, most strongly with KCl followed by NaCl and NHCl. Mixed solubility results were observed for perfluorooctanoate (PFOA) and perfluorooctane sulfonate (PFOS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!