Images of the kidneys using dynamic contrast-enhanced magnetic resonance renography (DCE-MRR) contains unwanted complex organ motion due to respiration. This gives rise to motion artefacts that hinder the clinical assessment of kidney function. However, due to the rapid change in contrast agent within the DCE-MR image sequence, commonly used intensity-based image registration techniques are likely to fail. While semi-automated approaches involving human experts are a possible alternative, they pose significant drawbacks including inter-observer variability, and the bottleneck introduced through manual inspection of the multiplicity of images produced during a DCE-MRR study. To address this issue, we present a novel automated, registration-free movement correction approach based on windowed and reconstruction variants of dynamic mode decomposition (WR-DMD). Our proposed method is validated on ten different healthy volunteers' kidney DCE-MRI data sets. The results, using block-matching-block evaluation on the image sequence produced by WR-DMD, show the elimination of of mean motion magnitude when compared to the original data sets, thereby demonstrating the viability of automatic movement correction using WR-DMD.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7010382 | PMC |
http://dx.doi.org/10.1007/s00138-017-0835-5 | DOI Listing |
Contemp Clin Dent
December 2024
Department of Orthodontics and Craniofacial Developmental Biology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
This article outlines the orthodontic treatment of a 21-year-old female patient with an open bite and temporomandibular joint disorders (TMDs) that developed after a severe car accident. The treatment plan utilized temporary anchorage devices (TADs) for upper molar intrusion to correct the open bite without resorting to orthognathic surgery. Over a period of 3 years, the treatment achieved a stable occlusion, normalized molar relationships, and improved esthetics.
View Article and Find Full Text PDFAim: Successful deep brain stimulation (DBS) requires precise electrode placement. However, brain shift from loss of cerebrospinal fluid or pneumocephalus still affects aim accuracy. Multidetector computed tomography (MDCT) provides absolute spatial sensitivity, and intraoperative cone-beam computed tomography (iCBCT) has become increasingly used in DBS procedures.
View Article and Find Full Text PDFFront Public Health
January 2025
Department of Movement and Training Science, University of Wuppertal, Wuppertal, Germany.
Introduction: This study investigated potential health status differences among forging, manufacturing, and logistics workers.
Methods: We included 403 participants (age: 41 ± 12 years) from a medium-sized steel company (forge: 64, manufacturing: 299, logistics: 99). Health status was multifactorial assessed: (1) Frequency of musculoskeletal complaints (German Pain Questionnaire).
Front Sociol
January 2025
National Consortium for the Study of Terrorism and Responses to Terrorism, University of Maryland, College Park, MD, United States.
[This corrects the article DOI: 10.3389/fsoc.2024.
View Article and Find Full Text PDFQuant Imaging Med Surg
January 2025
School of Medicine, Nankai University, Tianjin, China.
Background: It is well known that dysfunction of thalamocortical circuity generates the motor signs that lead to distinct disease processes and prognoses in Parkinson's disease (PD). This study aimed to leverage ultrahigh-field magnetic resonance imaging (MRI) to identify the connectivity alterations of thalamocortical circuity and clarify their relation to motor signs in early PD.
Methods: Patients with early-stage PD (n=55) and healthy controls (HCs, n=56) were recruited from March 2022 to July 2023.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!