Steroids that contain a 3-hydroxyl group (3-OH steroids) are widely distributed in nature. During analysis with ESI-MS, they easily become dehydrated while in the protonated form, resulting in the production of several precursor ions and leading to low sensitivity of detection. To address this analytical challenge, here, we developed a method for the quantitation of 3-OH steroids by LC-MS/MS coupled with post-column addition of lithium (Li) ions to the mobile phase. The Li ion has a high affinity for the keto group of steroids, stabilizing their structures during ionization and permitting detection of analytes exclusively as the lithiated form. This not only improved the intensities of the precursor ions, but also promoted the formation of typical lithiated fragment ions. This improvement made the quantitation by multiple reaction monitoring more sensitive and reliable, as evidenced by 1.53-188 times enhanced detection sensitivity of 13 steroids that contained at least one keto and two hydroxyl groups or one keto and one 5-olefinic double bond, among 16 different 3-OH steroids. We deployed our newly developed method for profiling steroids in mouse brain tissue and identified six steroids in one tissue sample. Among these, 16-hydroxyestrone, tetrahydrocorticosterone, and 17α-hydroxypregnenolone were detected for the first time in the mouse brain. In summary, the method described here enables the detection of lithiated steroids by LC-MS/MS, including three 3-OH steroids not previously reported in the mouse brain. We anticipate that this new method may allow the determination of 3-OH steroids in different brain regions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7112144PMC
http://dx.doi.org/10.1194/jlr.D119000588DOI Listing

Publication Analysis

Top Keywords

3-oh steroids
20
mouse brain
12
steroids
11
precursor ions
8
developed method
8
steroids lc-ms/ms
8
3-oh
5
lithium ion
4
ion adduction
4
adduction enables
4

Similar Publications

In this work, a series of novel Pterostilbene-oxime ether-carboxylic acid (POC) derivatives (d1-d10, e1-e10 and 1-13) were designed, synthesized, and characterized by spectroscopic techniques. In order to further determine the absolute configuration of these compounds, one of them, compound d3, was investigated by X-ray single crystal diffraction method. d3 had a triclinic crystal with P-1 space group, and its CHCH and CHN was confirmed as E configuration.

View Article and Find Full Text PDF

Rationale: Stanozolol, an anabolic androgenic steroid listed in Part S1 of the World Anti-Doping Agency Prohibited List, exhibits a low response and significant matrix interference in urine samples when using liquid-liquid extraction-gas chromatography-mass spectrometry (GC-MS). Enhancing sample preparation techniques remains essential for the effective detection of stanozolol and its metabolites.

Methods: A method for determining stanozolol and its metabolites (3'-OH-stanozolol, 4β-OH-stanozolol, and 16β-OH-stanozolol) in human urine was developed and validated using GC-Orbitrap high-resolution MS combined with optimized mixed-mode solid-phase extraction (SPE).

View Article and Find Full Text PDF

Structure-guided discovery of bile acid derivatives for treating liver diseases without causing itch.

Cell

December 2024

Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China; Peking-Tsinghua Center for Life Sciences, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China; Institute for Cancer Research, Shenzhen Bay Laboratory, Shenzhen 518107, China. Electronic address:

Chronic itch is a debilitating symptom profoundly impacting the quality of life in patients with liver diseases like cholestasis. Activation of the human G-protein coupled receptor, MRGPRX4 (hX4), by bile acids (BAs) is implicated in promoting cholestasis itch. However, the detailed underlying mechanisms remain elusive.

View Article and Find Full Text PDF

Shy (side chain hydratase) and Sal (side chain aldolase), are involved in successive reactions in the pathway of bile acid side chain catabolism in Proteobacteria. Untagged Shy copurified with His-tagged Sal indicating that the two enzymes form a complex. Shy contains a MaoC and a DUF35 domain.

View Article and Find Full Text PDF

Liquid Chromatography Coupled to Isotope Ratio Mass Spectrometry Expanded to Include Organic Mobile Phases.

Anal Chem

May 2024

Dell Pediatric Research Institute, Dell Medical School, University of Texas at Austin, 1400 Barbara Jordan Boulevard, Austin, Texas 78723, United States.

Current commercially available liquid chromatography coupled to isotope ratio mass spectrometry systems (LC-IRMS) oxidize all eluent and thus can only operate with all-aqueous mobile phases, limiting their application to a small subset of analytes and mixtures that can be separated without organic solvents. We report a novel rotating-catalytic disc desolvation device with subsequent laser-activated photocatalytic analyte combustion to create CO for high precision carbon isotope ratio measurements compatible with both aqueous and organic liquid mobile phases. Sucrose, glucose, androsterone, or androsterone acetate in 20% and 50% HO-CHOH solutions were introduced by flow injection to the interface to IRMS for sugars and steroids, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!