Optimization and reaction kinetics on the removal of Nickel and COD from wastewater from electroplating industry using Electrocoagulation and Advanced Oxidation Processes.

Heliyon

Study Program of Civil Engineering-Specialization in Environmental Engineering, Departement of Civil Engineering, Faculty of Engineering, Indonesia University, Depok, 16424, Indonesia.

Published: February 2020

Suzuki Indomobil Motor Plant (SIMP) Cakung, East Jakarta, Indonesia generates wastewater containing heavy metals such as nickel, zinc, chromium, copper, and COD derived from the metal coating process using the electroplating system. Electroplating wastewater produced by this company contains Nickel and COD above the quality standards set by the Government of DKI Jakarta (Governor Regulation No. 69/2013). This research aims to analyze and compare the efficiency and kinetics of Nickel complexes and COD removal using the Advanced Oxidation Process (AOP) and Electrocoagulation (EC) method. Electroplating wastewater generated by SIMP Cakung (ratio of plating wastewater to overflow plating wastewater is 1:30) in this study had characteristics of 379-568 ppm (effluent standard = 75 ppm) of COD, and 87.555-121 ppm (effluent standard = 1 ppm) of Nickel. Preliminary experiments with the factorial design method indicated that independent variables (pH, current density, ozone flow rate, and contact time) had a critical influence/significance on the removal efficiency of Nickel complexes, while the influence of the above variables in COD removal efficiency was not significant. Optimum operating conditions for Nickel complexes and COD removal using both AOP and EC reactor were found in this study as well as the reaction kinetics of the removal rate. Our study found that the optimum operating conditions for Nickel complexes and COD removal using the AOP reactor were at the pH of 10, the ozone flow rate of 2 L/min, the contact time of 60 min (99.75% and 51.25% for Nickel and COD removal, respectively). For the EC reactor, the optimum condition for Nickel and COD removal are pH of 6.5, the current density of 20 mA/cm and the contact time of 50 min (99.75% and 51.25% for Nickel and COD removal, respectively). In these conditions, the AOP reactor in its optimum condition could remove Nickel and COD more compared to the EC reactor. This finding suggests that AOP technology is not only reliable in removing Nickel from electroplating industrial wastewater, but also it could reduce the loading of COD for further treatment units by more than 50%. Further studies in the effect of the longer contact time and higher ozone flowrate on COD removal is suggested.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7031355PMC
http://dx.doi.org/10.1016/j.heliyon.2020.e03319DOI Listing

Publication Analysis

Top Keywords

cod removal
32
nickel cod
24
nickel complexes
16
contact time
16
cod
14
nickel
13
complexes cod
12
aop reactor
12
removal
11
reaction kinetics
8

Similar Publications

Electrolyte reactivity on electrode surfaces for active species formation and Reactive Red X-3B degradation in electrochemical treatment of dyeing wastewater.

J Environ Manage

January 2025

School of Environment Science and Engineering, Donghua University, Shanghai, 201620, PR China; Shanghai Institution of Pollution Control and Ecological Security, Shanghai, 200092, PR China; State Environmental Protection Engineering Center for Pollution Treatment and Control in Textile Industry, Donghua University, Shanghai, 201620, PR China.

The pivotal role of electrolytes such as NaSO and NaCl in electrochemical treatment of dyeing wastewater was investigated by comparing recalcitrant Reactive Red X-3B (RRX-3B) degradation rates, active species formation and intermediates generation in a double-chamber cell. It was found that similar reactive oxygen species (ROS) formed in the anodic chamber are OH and O, in the cathodic chamber is O with different electrolytes, while this is not the case for ROS contribution, RRX-3B degradation kinetic and intermediates. NaCl favored the generation of O, faster decolorization (-N=N- cleavage), and organic intermediates degradation in the anodic chamber.

View Article and Find Full Text PDF

Ethanol fermentation of tapioca wastewater in anaerobic baffled reactor: Performance evaluation and microbial community analysis.

Bioresour Technol

January 2025

Department of Science of Technology Innovation, Nagaoka University of Technology, Niigata 940-2188, Japan; Department of Civil and Environmental Engineering, Nagaoka University of Technology, Niigata 940-2188, Japan.

Anaerobic treatment of tapioca wastewater has a long processing time. This study aims to evaluate ethanol fermentation as an effective treatment of tapioca wastewater. Simulated tapioca wastewater with an average chemical oxygen demand (COD) of 6900 mg L was treated in a four-column anaerobic baffled reactor for 300 d.

View Article and Find Full Text PDF

A solar-powered electrocoagulation process with a novel CNT/silver nanowire coated basalt fabric cathode for effective oil/water separation: From fundamentals to application.

J Environ Manage

January 2025

Xinjiang Key Laboratory of Separation Material and Technology, The Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Urumqi, 830011, China; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China. Electronic address:

Electrocoagulation (EC) has proven its high efficiency and environmental sustainability for treating several types of wastewaters. However, the primary drawbacks of the conventional EC process are the suitable electrode materials and the relatively high cost due to the requirement for electric energy. To overcome these practical challenges, this study investigated effective oil/water separation by a solar-powered electrocoagulation (SPEC) process using a novel highly conductive basalt fabric (BF) cathode.

View Article and Find Full Text PDF

Cyanobacterial phycoremediation: a sustainable approach to dairy wastewater management.

Environ Technol

January 2025

Botany Discipline, School of Biological Sciences and Biotechnology, Goa University, Goa, India.

The dairy industry is a significant sector within the food industries, known for its high-water consumption and consequent generation of dairy wastewater (DWW), which is rich in pollutants like Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD). Improper disposal of DWW poses serious environmental challenges, including eutrophication and highlighting the need for sustainable biological treatment methods. This study investigates the potential of indigenous cyanobacterial strains , , , and for the bioremediation of DWW.

View Article and Find Full Text PDF

Nitrogen removal from multi-electrolyte saline wastewater via mainstream anammox in warm climate conditions.

J Environ Manage

January 2025

Biological Processes Laboratory (LPB), São Carlos School of Engineering (EESC), University of São Paulo (USP), Av. João Dagnone, 1100, Santa Angelina, São Carlos, São Paulo, 13563-120, Brazil.

Article Synopsis
  • High salt concentrations in wastewater present challenges to biological treatment, specifically impacting the anammox process, which has been primarily studied with NaCl.
  • This study examined the treatment of multi-electrolyte saline wastewater over 684 days, finding that anammox bacteria adapted well to increasing salinity levels, achieving 84.3% nitrogen removal efficiency at 0.72 wt%.
  • The research indicated that while the presence of residual organic matter shifted the metabolic pathway, the anammox process remained dominant, accounting for 83% of nitrogen removal despite changes in bacterial community structure.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!