Measurement of the concentration of hippurate in the inferior vena cava and renal blood samples performed in 13 subjects with normal or near-normal serum creatinine concentrations confirmed the prediction that endogenous hippurate was cleared on a single pass through the kidney with the same avidity as that reported for infused para-amino hippurate. This suggests that a timed urine collection without infusion would provide a measure of effective renal plasma flow. Comparison of the arteriovenous concentration differences for a panel of protein-bound solutes identified solutes that were secreted by the renal tubule and solutes that were subjected to tubular reabsorption.