A silica-based MCM-41 mesoporous material functionalized with cyanopropyl groups has been synthesized by cocondensation, characterized and applied to preconcentrate six parabens and three UV filters in river and swimming-pool waters. The analytes were quantified by ultra-high performance liquid chromatography-tandem mass spectrometry, according to the Directive 96/23/EC. Even though matrix effect was negligible, quantification in river water samples with the standard addition approach improved the recoveries obtained using solvent-based and even with matrix-matched calibration. The method quantification limits in river water samples were 0.05 ng/mL for 2,4-dihydroxybenzophenone and 0.01 ng/mL for the rest. Recoveries, evaluated for a concentration level of 0.5 ng/L, were in the range 93.5-107.6% for parabens and in the range 64.2-85.8% for UV filters, with relative standard deviations intraday ≤10.2 and 10.8%, respectively. This parameter, evaluated for a concentration level of 0.1 ng/L, ranged between 98.3 and 110.4% for parabens and between 61.9 and 89.9% for UV filters, with relative standard deviation intraday ≤15.3 and 15.5%, respectively. The two UV filters with lower recoveries were the most affected by the addition of sodium chloride. River and swimming pool waters were analyzed and all the personal care products were found in the swimming pool water, whereas only methylparaben was detected in the river water.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jssc.201901148 | DOI Listing |
Environ Sci Pollut Res Int
January 2025
South African Institute for Aquatic Biodiversity, Makhanda, 6140, South Africa.
Riverine physical and chemical characteristics are influencing ecosystem integrity while shaping and impacting species richness and diversity. Changes in these factors could potentially influence community structuring through competition, predation and localised species extinctions. In this study, eight sampling sites over multiple seasons were assessed along the streams draining the City of Nelspruit, South Africa, to examine river health based on water and sediment quality, while using macroinvertebrates as bioindicators for pollution.
View Article and Find Full Text PDFEnviron Sci Pollut Res Int
January 2025
Center for Environmental Sustainability and Water Security (IPASA), Research Institute for Sustainable Environment (RISE), Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia.
In the Johor River Basin, a comprehensive analysis was conducted on 24 water environmental parameters across 33 sampling sites over 3 years, encompassing both dry and wet seasons. A total of 396 water samples were collected and analyzed to calculate the Water Quality Index (WQI). To further assess water quality and pinpoint potential pollution sources, multivariate techniques such as principal component analysis (PCA) and cluster analysis (CA), alongside spatial analysis using inverse distance weighted (IDW) interpolation, were employed.
View Article and Find Full Text PDFAnal Methods
January 2025
State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, China.
Dichloroacetic acid (DCAA), trichloroacetic acid (TCAA), and bromate (BrO) are disinfection byproducts (DBPs) formed during drinking water treatment and pose health risks. Rapid and reliable detection of these DBPs is essential for ensuring water safety. Non-suppressed ion chromatography (IC)-electrospray ionization mass spectrometry (IC-ESI-MS/MS) offers a promising approach for simultaneous analysis of organic haloacetic acids (HAAs) and inorganic oxyhalides, but previous methods using toxic methylamine can pose health risks.
View Article and Find Full Text PDFFront Microbiol
December 2024
Meat Safety and Quality Research Unit, U.S. Department of Agriculture, U.S. Meat Animal Research Center, Clay Center, NE, United States.
Recent application of whole genome sequencing in the investigation of foodborne illness outbreaks has facilitated the identification of Reoccurring, Emerging, or Persistent (REP) bacterial strains that have caused illnesses over extended periods of time. Here, the complete genomes of two O157:H7 (EcO157) outbreak strains belonging to REPEXH01 and REPEXH02, respectively, were sequenced and annotated. Comparative genomics and phenotypic analyses were carried out to identify REP-associated traits.
View Article and Find Full Text PDFAnn Agric Environ Med
December 2024
Faculty of Environmental Engineering, Lublin University of Technology, Lublin, Poland.
Objective: The aim of the study is to verify whether the electronic nose system - an array of 17 gas sensors with a signal analysis system - is a useful tool for the classification and preliminary assessment of the quality of drainage water.
Material And Methods: Water samples for analysis were collected in the Park Ludowy (People's Park), located next to the Bystrzyca River, near the city center of Lublin in eastern Poland. Drainage water was sampled at 4 different points.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!