A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Camera Calibration with Weighted Direct Linear Transformation and Anisotropic Uncertainties of Image Control Points. | LitMetric

Camera Calibration with Weighted Direct Linear Transformation and Anisotropic Uncertainties of Image Control Points.

Sensors (Basel)

Scuola Superiore Sant'Anna, TeCIP Institute, Via Giuseppe Moruzzi 1, 56127 Pisa, Italy.

Published: February 2020

Camera calibration is a crucial step for computer vision in many applications. For example, adequate calibration is required in infrared thermography inside gas turbines for blade temperature measurements, for associating each pixel with the corresponding point on the blade 3D model. The blade has to be used as the calibration frame, but it is always only partially visible, and thus, there are few control points. We propose and test a method that exploits the anisotropic uncertainty of the control points and improves the calibration in conditions where the number of control points is limited. Assuming a bivariate Gaussian 2D distribution of the position error of each control point, we set uncertainty areas of control points' position, which are ellipses (with specific axis lengths and rotations) within which the control points are supposed to be. We use these ellipses to set a weight matrix to be used in a weighted Direct Linear Transformation (wDLT). We present the mathematical formalism for this modified calibration algorithm, and we apply it to calibrate a camera from a picture of a well known object in different situations, comparing its performance to the standard DLT method, showing that the wDLT algorithm provides a more robust and precise solution. We finally discuss the quantitative improvements of the algorithm by varying the modules of random deviations in control points' positions and with partial occlusion of the object.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7071080PMC
http://dx.doi.org/10.3390/s20041175DOI Listing

Publication Analysis

Top Keywords

control points
20
camera calibration
8
weighted direct
8
direct linear
8
linear transformation
8
control
8
control points'
8
points
5
calibration
5
calibration weighted
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!