AI Article Synopsis

  • The study aimed to assess the predictors and safety of next-day discharge (NDD) after transfemoral transcatheter aortic valve implantation (TF-TAVI) in patients using either balloon-expandable or self-expanding devices.
  • Conducted from 2007 to 2018, the study involved 1,232 patients averaging 80.9 years, with 13% discharged within 24 hours; there were no significant differences in mortality or complications between those discharged early and later.
  • Prior permanent pacemaker implantation and preprocedural computed tomography angiography were identified as predictors of NDD, suggesting that this discharge strategy is safe for patients without major complications.

Article Abstract

Aims: The aim of this study was to evaluate predictors and safety of next-day discharge (NDD) after transfemoral transcatheter aortic valve implantation (TF-TAVI) in unselected patients receiving either balloon-expandable or self-expanding devices.

Methods And Results: From June 2007 to August 2018, 1,232 consecutive patients undergoing TF-TAVI were discharged alive from our institution. They had a mean age of 80.9±5.4 years and an intermediate estimated surgical mortality risk; they received either balloon-expandable (26.1%) or self-expanding prostheses (73.9%). We compared patients discharged within 24 hours from the procedure (n=160, 13.0%) with those discharged later, and accounted for confounding variables through a propensity matching adjustment. After adjustment, no differences in all-cause mortality (1.2% vs 0.0%, for NDD and no-NDD matched groups, respectively, p=0.16) or permanent pacemaker implantation (PPI) after TAVI (0.6% vs 0.6%, respectively) were encountered at 30 days. At one year, no difference in the composite endpoint of all-cause death and heart failure (HF) rehospitalisation was encountered (Kaplan-Meier [KM] estimates 91.9% vs 90.6% for NDD and no-NDD matched groups, respectively, p=0.69). After excluding patients with post-procedural major complications from the unmatched population, prior PPI (OR 2.06, 95% CI: 1.21-3.51; p<0.01) and availability of preprocedural computed tomography angiography (CTA) (OR 1.71, 95% CI: 1.15-2.54; p<0.01) were found to be predictors of NDD after TAVI.

Conclusions: NDD in unselected patients after TF-TAVI using either balloon-expandable or self-expanding devices was demonstrated to be a safe strategy up to one year in the absence of procedural complications. Patients with prior PPI and undergoing preprocedural CTA had a higher chance of NDD.

Download full-text PDF

Source
http://dx.doi.org/10.4244/EIJ-D-19-01080DOI Listing

Publication Analysis

Top Keywords

predictors safety
8
safety next-day
8
next-day discharge
8
patients undergoing
8
transfemoral transcatheter
8
transcatheter aortic
8
aortic valve
8
valve implantation
8
ndd no-ndd
8
no-ndd matched
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!