A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In vitro histomechanical effects of enzymatic degradation in carotid arteries during inflation tests with pulsatile loading. | LitMetric

In vitro histomechanical effects of enzymatic degradation in carotid arteries during inflation tests with pulsatile loading.

J Mech Behav Biomed Mater

Mines Saint-Etienne, University of Lyon, INSERM, U1059 Sainbiose, 42023, Saint-Etienne, France. Electronic address:

Published: March 2020

In this paper, the objective is to assess the histomechanical effects of collagen proteolysis in arteries under loading conditions reproducing in vivo environment. Thirteen segments of common porcine carotid arteries (8 proximal and 5 distal) were immersed in a bath of bacterial collagenase and tested with a pulsatile tension/inflation machine. Diameter, pressure and axial load were monitored throughout the tests and used to derive the stress-stretch curves and to determine the secant circumferential stiffness. Results were analysed separately for proximal and distal segments, before and after 1, 2 and 3 h of enzymatic degradation. A histological analysis was performed to relate the arterial microstructure to its mechanical behavior under collagen proteolysis. Control (before enzymatic degradation) and treated populations (after 1, 2 or 3 h of enzymatic degradation) were found statistically incomparable, and histology confirmed the alteration of the fibrous structure of collagen bundles induced by the collagenase treatment. A decrease of the secant circumferential stiffness of the arterial wall was noticed mostly at the beginning of the treatment, and was less pronounced after 1 h. These results constitute an important set of enzymatically damaged arteries that can be used to validate biomechanical computational models correlating structure and properties of blood vessels.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2019.103550DOI Listing

Publication Analysis

Top Keywords

enzymatic degradation
16
histomechanical effects
8
carotid arteries
8
collagen proteolysis
8
proximal distal
8
secant circumferential
8
circumferential stiffness
8
3 h enzymatic
8
vitro histomechanical
4
enzymatic
4