Mechanistic understanding of compression-compression fatigue behavior of functionally graded Ti-6Al-4V mesh structure fabricated by electron beam melting.

J Mech Behav Biomed Mater

Department of Metallurgical, Materials, and Biomedical Engineering, University of Texas at El Paso, 500 W. University Avenue, El Paso, TX, 79968, USA.

Published: March 2020

AI Article Synopsis

Article Abstract

In recent years, mesh structures have attracted significant interest for structural and functional applications. However, the mechanical strength and energy absorption ability of uniform mesh structured materials degrade with density. To address this challenge, we propose the concept of functionally graded mesh structures. The objective of the proposed research is to fundamentally understand the compressive behavior of graded mesh structures. The compression-compression fatigue behavior of functionally graded Ti-6Al-4V mesh structure under identical bulk stress condition is studied here. During cyclic deformation, it was observed that the local stress distribution in the struts was not uniform because of inhomogeneous mechanical properties of the constituents. Fatigue cracks first initiated in the lowest strength constituent, and then propagated until structural failure occurred. However, no obvious damage was observed in other constituents during the entire process. In contrast with iso-strain state, the fatigue life of graded structure is mainly determined by the constituent with the lowest strength.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2019.103590DOI Listing

Publication Analysis

Top Keywords

functionally graded
12
mesh structures
12
compression-compression fatigue
8
fatigue behavior
8
behavior functionally
8
graded ti-6al-4v
8
ti-6al-4v mesh
8
mesh structure
8
graded mesh
8
lowest strength
8

Similar Publications

Radiation pneumonitis (RP) is characterized by inflammation and is associated with autophagy. However, the relationship between functional genetic variants of autophagy-related genes and radiation pneumonitis remains unknow. In this study we aimed to investigate whether genetic variants of genes involved in autophagy are associated with radiation pneumonitis.

View Article and Find Full Text PDF

Fear avoidance (FA) describes beliefs and behaviors related to avoiding movements or activities after a painful event. FA is a prevalent issue that limits the recovery outcomes and social reintegration of burn survivors. However, as current literature focuses on chronic conditions, understanding the impact and treatment of FA within sudden onset musculoskeletal (MSK) conditions, specifically in the burn survivor population, is lacking.

View Article and Find Full Text PDF

Introduction: We describe the safety of sotorasib monotherapy in patients with KRAS G12C-mutated advanced non-small cell lung cancer (NSCLC) and discuss practical recommendations for managing key risks.

Methods: Incidence rates of treatment-related adverse events (TRAEs) were pooled from 4 clinical trials: CodeBreaK 100 (NCT03600883), CodeBreaK 101 (NCT04185883), CodeBreaK 105 (NCT04380753), and CodeBreaK 200 (NCT04303780) and graded according to CTCAE v5.0.

View Article and Find Full Text PDF

Synthetic Bilirubin-Based Nanomedicine Protects Against Renal Ischemia/Reperfusion Injury Through Antioxidant and Immune-Modulating Activity.

Adv Healthc Mater

January 2025

Department of Biological Sciences, KAIST Institute for the BioCentury, Center for Precision Bio-Nanomedicine, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea.

Renal ischemia/reperfusion injury (IRI) is a common form of acute kidney injury. The basic mechanism underlying renal IRI is acute inflammation, where oxidative stress plays an important role. Although bilirubin exhibits potent reactive oxygen species (ROS)-scavenging properties, its clinical application is hindered by problems associated with solubility, stability, and toxicity.

View Article and Find Full Text PDF

Quantitative profiling and mapping of small molecules by laser desorption/ionization mass spectrometry: combinations of carbon-based nano-matrices and sample preparation protocols.

Analyst

January 2025

Jiangsu Key Laboratory for Carbon-based Functional Materials and Devices, Institute of Functional Nano and Soft Materials (FUNSOM), Soochow University, Suzhou, Jiangsu Province 215123, China.

The choices of matrices and protocols for sample deposition are critical factors, which impact each other in the matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI). Previous reports on MALDI MS matrices have only compared their performances in terms of their MS signal intensities and provided optical microphotos or MALDI MS images of sample spots but typically lacked quantitative evaluation. Therefore, there is an urgent need to develop a multivariate model to evaluate the performance of different combinations of matrices and sample protocols.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!