Objectives: To compare accuracy between Premaquick (combined test for native insulin-like growth factor binding protein-1 (IGFBP-1), total IGFBP-1, and interleukin-6) and fetal fibronectin (Ffn) in predicting preterm delivery.
Methods: Prospective study among women at 28-36 gestational weeks with threatened preterm labor attending Federal Medical Center, Owerri, Nigeria, from August 2017 to February 2019. Cervico-vaginal fluids were collected and tested by Premaquick and Ffn tests. The women were followed for 14 days. Sensitivity, specificity, and negative (NPV) and positive (PPV) predictive value for delivery were compared between the tests.
Results: Among 213 women assessed for eligibility, 183 were enrolled and 175 completed the study. The sensitivity, specificity, PPV, NPV, and accuracy of the Premaquick versus Ffn tests were, respectively, 96.3% versus 51.9%, 97.6% versus 98.4%, 89.7% versus 87.5%, 99.2% versus 90.3% and 97.3% versus 90.0% for preterm delivery within 14 days. Ffn had higher specificity (98.5% vs 97.8%; P>0.99), but Premaquick had higher PPV (92.7% vs 90.9%; P>0.99).
Conclusion: Both tests seem to have high utility in predicting preterm delivery, but Premaquick showed higher accuracy in terms of sensitivity and PPV. Premaquick might be a feasible alternative to Ffn for predicting preterm delivery among symptomatic women in a low-income setting.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ijgo.13128 | DOI Listing |
Ultrasound Obstet Gynecol
January 2025
Discipline of Obstetrics, Gynaecology and Neonatology, Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia.
Objective: To assess the performance of the Fetal Medicine Foundation (FMF) first-trimester competing-risks screening model for small-for-gestational-age (SGA) fetuses requiring delivery at < 37 weeks' gestation, in a large cohort of women receiving maternity care in Australia.
Methods: This was a retrospective analysis of prospectively collected data from a cohort of women attending one of two private multicenter fetal medicine practices for first-trimester screening for preterm pre-eclampsia (PE), defined as PE requiring delivery before 37 weeks' gestation. Risk for preterm SGA, defined as SGA requiring delivery before 37 weeks, was calculated but was not disclosed to the patient or referring physician.
Ultrasound Obstet Gynecol
January 2025
Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, SAR, China.
Objectives: To compare the maternal hemodynamic profile at 12 + 0 to 15 + 6 weeks' gestation in women who subsequently developed pre-eclampsia (PE) and those who did not, and to assess the screening performance of maternal hemodynamic parameters for PE in combination with the Fetal Medicine Foundation (FMF) triple test, including maternal factors (MF), mean arterial pressure (MAP), uterine artery pulsatility index and placental growth factor.
Methods: This was a prospective case-control study involving Chinese women with a singleton pregnancy who underwent preterm PE screening at 11 + 0 to 13 + 6 weeks' gestation using the FMF triple test, between February 2020 and February 2023. Women identified as being at high risk (≥ 1:100) for preterm PE by the FMF triple test were matched 1:1 with women identified as low risk (< 1:100) for maternal age ± 3 years, maternal weight ± 5 kg and date of screening ± 14 days.
J Coll Physicians Surg Pak
January 2025
Department of Obstetrics and Gynaecology, Health Sciences University, Bursa Yuksek Ihtisas Training and Research Hospital,
Bursa, Turkiye.
Objective: To compare the inflammatory markers between therapeutic and emergency cerclage and assess the predictive role of inflammatory markers for the latency period.
Study Design: Descriptive study. Place and Duration of the Study: Department of Obstetrics and Gynaecology, Bursa Yuksek Ihtisas Training and Research Hospital, Turkiye, from January 2016 to September 2022.
Eur J Pediatr
January 2025
Hospital de Clinicas de Porto Alegre, Rua Silva Jardim 1155 # 701, Porto Alegre, RS, 90450-071, Brazil.
Unlabelled: To evaluate the accuracy of the lung ultrasound score (LUS) in predicting ventilatory weaning failure during neonatal hospitalization in the NICU and to identify factors associated with weaning failure, including corrected gestational age (CGA). This prospective, longitudinal, pragmatic and observational cohort study included neonates on mechanical ventilation for at least 48 h. The primary outcome was the accuracy of lung ultrasound in predicting 3-day weaning failure, with the ROC curve used to determine the best LUS cutoff (sensitivity and specificity).
View Article and Find Full Text PDFSci Rep
January 2025
Department of Pediatrics, Division of Infectious Diseases, Ann & Robert H. Lurie Children's Hospital of Chicago, Northwestern University Feinberg School of Medicine, Chicago, IL, USA.
Neonatal health is dependent on early risk stratification, diagnosis, and timely management of potentially devastating conditions, particularly in the setting of prematurity. Many of these conditions are poorly predicted in real-time by clinical data and current diagnostics. Umbilical cord blood may represent a novel source of molecular signatures that provides a window into the state of the fetus at birth.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!