A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of digitization obtained from scannable and nonscannable elastomeric impression materials. | LitMetric

Accuracy of digitization obtained from scannable and nonscannable elastomeric impression materials.

J Prosthet Dent

Professor and Associate Dean, Department of Buccofacial Prostheses, Faculty of Dentistry, Universidad Complutense de Madrid, Madrid, Spain.

Published: February 2021

Statement Of Problem: Elastomeric impression materials have been marketed for optimizing direct digital acquisition without requiring a stone cast. The trueness and precision of the digitization of these new elastomeric impression materials are unclear.

Purpose: The purpose of this in vitro study was to compare the trueness and precision of digital dental casts obtained from the direct digitization of 2 types of vinylsiloxanether (VSXE) impression materials by using a laboratory laser scanner.

Material And Methods: Thirty-eight elastomeric impressions were made of a master die with a similar morphology to a premolar crown preparation. The impression materials were Identium (IDE) and Identium Scan (SCAN), designed for direct digitalization. Each impression was digitalized by using an optical scanner to create digital casts. A computer-aided design (CAD) reference model of trueness (CRM) was created and aligned to each digital cast for digital 3-dimensional discrepancy analysis.

Results: The mean ±standard deviation global trueness of IDE was 53 ±16 μm and that of SCAN was 46 ±3 μm. SCAN digital casts showed higher precision (58 ±5 μm) than IDE (69 ±18 μm) (P<.05). At the margin of the preparation and at the axial surfaces, SCAN models showed higher trueness (3 ±6 μm and 1 ±5 μm) than IDE (15 ±10 μm and 2 ±37 μm), respectively.

Conclusions: Scannable impressions could be digitalized with higher global precision than conventional elastomeric materials. Higher trueness could be achieved in specific impression locations such as gingival areas or axial walls of preparations, where the light emitted by the scanner was not blocked.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2020.01.002DOI Listing

Publication Analysis

Top Keywords

impression materials
20
elastomeric impression
12
trueness precision
8
digital casts
8
μm scan
8
impression
6
digital
6
materials
5
accuracy digitization
4
digitization scannable
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!