Purpose: To accelerate coronary MRI acquisitions with arbitrary undersampling patterns by using a novel reconstruction algorithm that applies coil self-consistency using subject-specific neural networks.
Methods: Self-consistent robust artificial-neural-networks for k-space interpolation (sRAKI) performs iterative parallel imaging reconstruction by enforcing self-consistency among coils. The approach bears similarity to SPIRiT, but extends the linear convolutions in SPIRiT to nonlinear interpolation using convolutional neural networks (CNNs). These CNNs are trained individually for each scan using the scan-specific autocalibrating signal (ACS) data. Reconstruction is performed by imposing the learned self-consistency and data-consistency, which enables sRAKI to support random undersampling patterns. Fully-sampled targeted right coronary artery MRI was acquired in six healthy subjects. The data were retrospectively undersampled, and reconstructed using SPIRiT, l1-SPIRiT and sRAKI for acceleration rates of 2 to 5. Additionally, prospectively undersampled whole-heart coronary MRI was acquired to further evaluate reconstruction performance.
Results: sRAKI reduces noise amplification and blurring artifacts compared with SPIRiT and l1-SPIRiT, especially at high acceleration rates in targeted coronary MRI. Quantitative analysis shows that sRAKI outperforms these techniques in terms of normalized mean-squared-error (~44% and ~21% over SPIRiT and [Formula: see text]-SPIRiT at rate 5) and vessel sharpness (~10% and ~20% over SPIRiT and l1-SPIRiT at rate 5). Whole-heart data shows the sharpest coronary arteries when resolved using sRAKI, with 11% and 15% improvement in vessel sharpness over SPIRiT and l1-SPIRiT, respectively.
Conclusion: sRAKI is a database-free neural network-based reconstruction technique that may further accelerate coronary MRI with arbitrary undersampling patterns, while improving noise resilience over linear parallel imaging and image sharpness over l1 regularization techniques.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7034900 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0229418 | PLOS |
Sci Rep
January 2025
Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
Subject-specific parameters in lumped hemodynamic models of the cardiovascular system can be estimated using data from experimental measurements, but the parameter estimation may be hampered by the variability in the input data. In this study, we investigate the influence of inter-sequence, intra-observer, and inter-observer variability in input parameters on estimation of subject-specific model parameters using a previously developed approach for model-based analysis of data from 4D Flow MRI acquisitions and cuff pressure measurements. The investigated parameters describe left ventricular time-varying elastance and aortic compliance.
View Article and Find Full Text PDFPediatr Cardiol
January 2025
Department of Pediatrics, Cincinnati Children's Hospital Medical Center, The Heart Institute, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
Cardiac-Urogenital Syndrome (CUGS) is a recently identified genetic disease characterized by urogenital, diaphragmatic, ophthalmic, and cardiac abnormalities caused by heterozygous pathogenic variants in the Myelin Regulatory Factor (MYRF) gene. The complete spectrum of disease characteristics and prevalence is not yet defined. This report documents the first known cases of anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) in MYRF-associated Cardiac-Urogenital Syndrome (MYRF-CUGS).
View Article and Find Full Text PDFRinsho Ketsueki
January 2025
Department of Hematology and Oncology, Tokai University School of Medicine.
A 54-year-old woman underwent cord blood transplantation in second remission of acute myeloid leukemia. She tested positive for anti-toxoplasma IgG antibody before transplantation. After neutrophil engraftment, she complained of foggy vision, but brain MRI showed no abnormality.
View Article and Find Full Text PDFBrain Behav
January 2025
Department of Neurology, Tianjin Key Laboratory of Cerebrovascular and Neurodegenerative Diseases, Clinical College of Neurology, Neurosurgery and Neurorehabilitation, Tianjin Huanhu Hospital, Tianjin Medical University, Tianjin, China.
Background: Respirator failure (RF) is a severe malignant complication in both lateral medullary infarction (LMI) and medial medullary infarction (MMI) patients. However, the differences in clinical and radiological manifestations associated with RF between patients with LMI and MMI have not been fully elucidated.
Methods: A total of 435 consecutive patients with MI within 7 days of onset in our institute were retrospectively enrolled from January 2017 to January 2024.
Ann Pediatr Endocrinol Metab
December 2024
Department of Pediatrics, Seoul National University Children's Hospital, Seoul, Korea.
Purpose: To investigate the clinical characteristics and genetic features of childhood-onset congenital combined pituitary hormone deficiency (cCPHD) in Korean patients.
Methods: We retrospectively analyzed 444 patients diagnosed with childhood-onset CPHD at a tertiary center between 1994 and 2021. After excluding acquired case, 43 patients with cCPHD were enrolled.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!