Background: This study aims to report our experience with esophageal self-expendable metal stents for the palliation of malignant dysphagia and tracheoesophageal fistulas caused by lung cancer.

Methods: Esophageal self-expandable metal stents were deployed in 56 patients (55 males, 1 female; mean age 63.5 years; range, 42 to 79 years) with malignant dysphagia due to lung cancer between August 2002 and May 2018. Of the patients, 34 had received previous chemoradiotherapy, eight only chemotherapy, and three only radiotherapy, while four had pneumonectomy. Tracheoesophageal fistula was coexisting in 12 patients (21%). Stents were inserted under fluoroscopic control over guide-wire in 28 patients and under flexible endoscopic control in the remaining 28 patients. One stent was used in all patients, except two patients with tracheoesophageal fistula, one patient who had an external compression causing downward migration of stent, and two patients who had tumor progression.

Results: Dysphagia improved in all patients after stent insertion. Tracheoesophageal fistula was sealed off in all patients. All patients remained asymptomatic without dysphagia symptoms during the follow-up period except for two patients who underwent gastrostomy. All patients with tracheoesophageal fistula died. Their mean duration of survival was 2.8 months. Of the patients with tracheoesophageal fistula, one died of mediastinitis, one died of esophageal perforation, while the others died of cancer-related reasons. Of the dysphagia patients without tracheoesophageal fistula, all died except for two patients. Mean duration of survival in this group was 4.3 months.

Conclusion: Dysphagia in lung cancer may have many underlying reasons. Self-expandable metal stents may provide satisfactory relief of dysphagia symptoms with minimal morbidity after a single procedure in patients with limited lifespan.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7021379PMC
http://dx.doi.org/10.5606/tgkdc.dergisi.2019.16755DOI Listing

Publication Analysis

Top Keywords

tracheoesophageal fistula
24
patients
17
patients tracheoesophageal
16
self-expandable metal
12
dysphagia lung
12
lung cancer
12
metal stents
12
fistula died
12
esophageal self-expandable
8
dysphagia
8

Similar Publications

Esophageal stricture is the most common and disabling complication of esophageal injury caused by ingestion of corrosive substances. In our case, the patient developed esophageal stenosis due to ingestion of strong alkaline substances and underwent colon replacement surgery after repeated failed dilation treatments. After surgery, anastomotic stenosis and tracheocolonic fistula occurred successively, and the entire diagnosis and treatment cycle of this disease lasted for more than 20 years.

View Article and Find Full Text PDF

Background: In cases of tracheoesophageal fistula (TEF), closure of the fistula by tracheal stent implantation is an effective treatment. In this study, we investigated the efficacy and complications of silicone and metallic tracheal stents for TEF.

Methods: We retrospectively reviewed all patients who underwent tracheal stent insertion for TEF between January 2021 and April 2024 at our institution.

View Article and Find Full Text PDF

Background: Elective ventilation and paralysis have been shown to decrease the anastomosis-related complications following primary repair of esophageal atresia (EA). Repeated endotracheal tube (ETT) block and replacement can increase these complications. We evaluated the results of our strategy of electively changing the ETT just before shifting the patient to the postoperative ward for elective ventilation.

View Article and Find Full Text PDF

Specific Findings of Blood Perfusion on Anastomosed Esophagus of Neonatal Esophageal Atresia and Tracheoesophageal Fistula Using Indocyanine Green Fluorescence During Thoracoscopic Surgery.

Asian J Endosc Surg

December 2024

Department of Pediatric Surgery, Research Field in Medical and Health Sciences, Medical and Dental Area, Research and Education Assembly, Kagoshima University, Kagoshima, Japan.

We herein report a neonatal case showing specific findings of blood perfusion in the anastomosed esophagus of esophageal atresia (EA) and tracheoesophageal fistula (TEF) using indocyanine green (ICG) fluorescence during thoracoscopic surgery. The patient was a 3054 g, 0-day neonatal boy diagnosed with EA-TEF based on a coil-up sign of the nasogastric tube. Thoracoscopic surgery was performed on Day 4 after birth.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!