A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Model-based correction algorithm for Fourier Transform infrared microscopy measurements of complex tissue-substrate systems. | LitMetric

Model-based algorithms have recently attracted much attention for data pre-processing in tissue mapping and imaging by Fourier transform infrared micro-spectroscopy (FTIR). Their versatility, robustness and computational performance enabled the improvement of spectral quality by mitigating the impact of scattering and fringing in FTIR spectra of chemically homogeneous biological systems. However, to date, no comprehensive algorithm has been optimized and automated for large-area FTIR imaging of histologically complex tissue samples. Herein, for the first time, we propose a unique, integrated and fully-automated Multiple Linear Regression Multi-Reference (MLR-MR) method for correcting linear baseline effects due to diffuse scattering, for compensating substrate thickness inhomogeneity and accounting for sample chemical heterogeneity in FTIR images. In particular, the algorithm uses multiple-reference spectra for histologically heterogeneous biological samples. The performance of the procedure was demonstrated for FTIR imaging of chemically complex rat brain frontal cortex tissue samples, mounted onto Ultralene® films. The proposed MLR-MR correction algorithm allows the efficient retrieval of "pure" absorbance spectra and greatly improves the histological fidelity of FTIR imaging data, as compared with the one-reference approach. In addition, the MLR-MR algorithm here presented opens up the possibility for extracting information on substrate thickness variability, thus enabling the indirect evaluation of its topography. As a whole, the MLR-MR procedure can be easily extended to more complex systems for which Mie scattering effects must also be eliminated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2019.12.070DOI Listing

Publication Analysis

Top Keywords

ftir imaging
12
correction algorithm
8
fourier transform
8
transform infrared
8
tissue samples
8
substrate thickness
8
ftir
6
algorithm
5
model-based correction
4
algorithm fourier
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!